Setting up the battery
Description of parameters
Parameter
Description
Battery serial
This parameter affects only the battery serial number displayed in
applications. You can enter your name there or the name of your repair
shop.
Battery capacity
Very important parameter, it must be set to the correct value, otherwise,
wrong charge level calculation during charge and discharge is possible.
Battery date of production
This parameter affects only the battery production date displayed in
applications.
Discharge curve
Sets the correlation between the voltage of the most discharged parallel and
the charge level, in percent, at 11 points. For example, by default, 0% is
3100mV, 10% is 3200mV, ..., 90% is 4000mV, 100% is 4100mV. Using this
setting, you can carefully adjust the uniformity of the charge level scale to the
non-linear characteristic of the battery cells you use.
Charge overcurrent
The maximum continuous charge current, exceeding which during the time
determined by the “Charge overcurrent delay” parameter, charging will be
disabled for the time determined by the “Charge overcurrent cooldown”
parameter.
Charge overcurrent delay
The time after which the protection against exceeding the charge current is
activated.
Charge overcurrent cooldown
The time during which charging will be disabled after the protection against
exceeding the charge current is activated.
Discharge overcurrent
The maximum continuous discharge current, exceeding which during the
time determined by the “Discharge overcurrent delay” parameter,
discharging will be disabled for the time determined by the “Discharge
overcurrent cooldown” parameter.
Discharge overcurrent delay
The time after which the protection against exceeding the discharge current
is activated.
Discharge overcurrent
cooldown
The time during which discharging will be disabled after the protection
against exceeding the discharge current is activated.
Short circuit current
The maximum continuous discharge current, exceeding which during the
time determined by the “Short circuit delay” parameter, discharging will be
disabled for the time determined by the “Short circuit cooldown” parameter.
Short circuit delay
The time after which the protection against short circuit is activated.
Short circuit cooldown
The time during which discharging will be disabled after the protection
against short circuit is activated.
(continued on the next page)