4.4.2.11 Set device to get acknowledge: AT+ACK
Form
Command
Return
Set
AT+ACK=<number string>
0K
ERROR
Query
AT+ACK?
+ACK: number string
OK
Attention :
whether or not to get the application level acknowledge data
Parameter description :
number strings range:
0 = No
1 = Yes
Default:0
4.4.2.12 Set device debug level: AT+DBL
Form
Command
Return
Set
AT+DBL=<number string>
0K
ERROR
Query
AT+DBL?
+DBL: number string
OK
Parameter description :
number strings range:
0 = Close all debug messages
1 = Info the important debug messages
2 = Info all debug messages
Default: 0