Configuration Maximum
Operating
Temperature 30°C
(86°F)
Maximum
Operating
Temperature 35°C
(95°F)
Maximum
Operating
Temperature 40°C
(104°F)
whose capacity is
256 GB per
module or larger
are not supported.
are not supported.
⚫
Rear drive
modules support
neither WD
Vela-AP (8 TB)
drives nor
Vela-AX (10 TB)
NL SAS drives.
100Gbit/s rate or
higher are not
supported.
⚫
DDR4/PMem
memory modules
whose capacity is
128 GB per
module or larger
are not supported.
⚫
When a single fan is faulty, the highest operating temperature is 5°C (9°F) lower than the rated
value.
⚫
When a single fan is faulty, the system performance may be affected.
⚫
It is recommended that servers be deployed at an interval of 1U to reduce server noise and improve
server energy efficiency.
⚫
I/O module 3 does not support hard disk drives (HDDs) when the server is configured with
processors of 205 W or higher power.
⚫
If front drives are not configured in slots 0 to 2, slots 6 to 8, slots 12 to 14, and slots 18 to 20, PMem
memory modules of 512 GB per module are supported. The maximum operating temperature is
30°C (86°F).
⚫
8368Q 38c 270 W 2.6 GHz liquid-cooled processors are not supported.
A.4 Nameplate
Certified Model
Remarks
H52H-06
Global
A.5 RAS Features
The server supports a variety of Reliability, Availability, and Serviceability (RAS) features.
You can configure these features for better performance.
For details about the RAS features, see
FusionServer Ice Lake Platform RAS Technical White
Paper
.
A.6 Sensor List
Sensor
Description
Component
Inlet Temp
Air inlet temperature
Right mounting ear
Outlet Temp
Air outlet temperature
BMC card