NO TE
● When a single fan is faulty, the highest operating temperature is 5°C (9°F) lower than the
rated value.
● When a single fan is faulty, the system performance may be affected.
● When memory modules of 256 GB per module or larger or 6342/6348/6346/6354/8352V/
8352S/8352Y/8358P/8351N/8358/8360Y/8368/8380 processors are configured, rear GPU
cards, rear drives (including HDDs, SSDs, and M.2), IB cards, or OCP 3.0 network
adapters with 25Gbit/s rate or higher are not supported.
● It is recommended that servers be deployed at an interval of 1 U to reduce server noise
and improve server energy efficiency.
● The server does not support 8368Q 38c 270 W 2.6 GHz liquid-cooled processors.
A.4 Nameplate
Certified Model
Usage Restrictions
H12H-06
Global
A.5 RAS Features
The server supports a variety of Reliability, Availability, and Serviceability (RAS)
features. You can configure these features for better performance.
For details about the RAS features, see
FusionServer Ice Lake Platform RAS
Technical White Paper
.
A.6 Sensor List
Sensor
Description
Component
Inlet Temp
Air inlet temperature
Indicator board
Outlet Temp
Air outlet temperature
BMC card
PCH Temp
PCH bridge temperature
Mainboard
CPU
N
Core Rem
CPU core temperature
CPU
N
N
indicates the CPU
number. The value is
1
or
2
.
CPU
N
DTS
Difference between the
real-time CPU
temperature and the core
CPU temperature
threshold
CPU
N
N
indicates the CPU
number. The value is
1
or
2
.
FusionServer 1288H V6 Server
Technical White Paper
A Appendix
Issue 10 (2023-04-30)
Copyright © xFusion Digital Technologies Co., Ltd.
91