Error Troubleshooting
Xerox Internal Use Only
Phaser 6600 and WorkCentre 6605
Service Manual
2-225
Other Fault Isolation Procedures
Abnormal Noise
FIP-N1 Abnormal Noise: When Power is Turned On
Step Check
Yes
No
Possible causative parts:
• Toner Cartridge (Y, M, C, K) (PL5.1.8?PL5.1.11)
• Dispenser Motor (Y,M,C,K) [Upper Dispenser Motor
Assembly] (PL5.1.1)
• Main Motor [Drive Assembly] (PL3.1.1)
1
Check the Dispense Motor operation
Execute Digital Output diagnostic test 093-004(Y), 093-
006(M), 093-008(C), and 093-010(K), and check the
Dispenser Motor rotation.
Is the device making an abnormal noise?
CAUTION:
Stop the Motor operation within 3
seconds, or the device will be damaged.
Go to step 2.
Go to step 3.
2
Check the Toner Cartridge installation
Reinstall the Toner Cartridge.
Turn the power off, and then on again. Is the device making
an abnormal noise?
Replace the
Toner Cartridge.
If the trouble still
exists, replace
the device.
Finished.
3
Check the Main Motor operation
Execute Digital Output diagnostic test 071-001, and check
the Main Motor rotation.
Is the device making an abnormal noise?
CAUTION:
Stop the Motor operation within 3
seconds, or the device will be damaged.
Replace the Main
Motor [Drive
Assembly].
Finished.
Summary of Contents for WorkCentre 6605
Page 2: ......
Page 4: ...Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual ii ...
Page 352: ...Image Quality Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual 3 26 ...
Page 568: ...Parts Lists Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual 5 64 ...
Page 644: ...Wiring Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual 7 52 ...
Page 654: ...Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual A 10 ...
Page 660: ...Index Phaser 6600 and WorkCentre 6605 Service Manual I 6 ...
Page 661: ......