WorkCentre 385
Fuser Error
12/98
2 - 10
Fuser Error
Measure the resistance of
the Fuser Halogen Lamp
at SMPS CN-1 & CN-2
with covers open.
Resistance
is less than 10 ohms?
Replace the Halogen Lamp (REP 4.28),
then the Thermostat (REP 4.29).
AC
power is being
supplied?
Replace the Engine PBA (REP 4.17),
then the Thermistor (REP 4.29).
Check wiring, then replace
the SMPS PBA (REP 4.17),
NO
YES
YES
NO
then the Engine PBA
(REP 4.17), then the
Thermistor (REP 4.29).