April 2017
2-509
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
116-341, 342, 393, 394, 116-343, 346, 357, 359
Status Indicator RAPs
Launch Issue
116-341, 342, 393, 394 ROM Version Incorrect RAP
116-341 Versions of the multiple ROM DIMMs installed are incorrect.
116-342 Fatal error related to the SNMP agent.
116-393 AAA manager fatal error.
116-394 Abnormal authentication mode and accounting mode settings detected during AAA
manager boot sequence.
Procedure
Reload the software,
GP 4
.
116-343, 346, 357, 359 Main PWB Error RAP
116-343 An error was detected in the IC in the ESS PWB.
116-346 A response such as system function recall error was detected.
116-357 PS Fatal System Error
116-359 Fatal error in PLW.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
GP 10
.
2.
Ensure that all connectors on the drive PWB,
PL 1.10 Item 3
and the ESS PWB,
PL 3.10
Item 6
are securely connected. Ensure all surface mounted modules on both PWBs are
securely connected.
3.
Reload the software,
GP 4
.
4.
Perform the
OF2
Special Boot Modes RAP.