April 2017
2-480
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
077-211, 077-212, 214, 215, 314
Launch Issue
Status Indicator RAPs
077-211 Tray Module Mismatch RAP
BSD-ON:
BSD 3.2 PWB Communications (ESS PWB/Drive PWB to STM)
BSD-ON:
BSD 3.3 PWB Communications (ESS PWB/Drive PWB to 1TM/3TM)
077-211 A tray module mismatch has occurred.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
GP 10
.
2.
Check the connections between the tray module and the machine.
3.
Enter
dC131
. Ensure that the tray module type is correctly set in NVM value 742-205:
•
1TM = 0
•
3TM = 1
•
TTM = 2
•
STM = 6
4.
If the fault persists, install new components as necessary:
•
1TM PWB,
PL 70.17 Item 5
.
•
3TM PWB,
PL 70.23 Item 5
.
•
STM PWB,
PL 70.28 Item 4
.
•
TTM PWB,
PL 70.90 Item 1
.
•
Drive PWB,
PL 1.10 Item 3
.
•
ESS PWB,
PL 3.10 Item 6
.
077-212, 214, 215, 314 Tray Module Communication Fail
RAP
BSD-ON:
BSD 1.7 Option DC Power Distribution
BSD-ON:
BSD 3.2 PWB Communications (ESS PWB/Drive PWB to STM)
BSD-ON:
BSD 3.3 PWB Communications (ESS PWB/Drive PWB to 1TM/3TM/TTM)
077-212 Tray module reset was detected.
077-214 Tray module fatal error was detected.
077-215 Reply from the tray module was detected as a communication error.
077-314 Tray module fatal error was detected.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
GP 10
.
2.
Check the items that follow: connections between the tray module and the machine:
•
The connection between the drive PWB (
P/J592
) and the STM PWB (
P/J541
).
•
The connection between the drive PWB (
P/J592
) and the 1TM PWB (
P/J541
).
•
The connection between the drive PWB (
P/J592
) and the 3TM PWB (
P/J541
).
•
The connection between the drive PWB (
P/J592
) and the TTM PWB (
P/J541
).
•
The connection between the drive PWB (
P/J401
) and the ESS PWB (
P/J1334
).
3.
If the fault persists, install new components as necessary:
•
1TM PWB,
PL 70.17 Item 5
.
•
3TM PWB,
PL 70.23 Item 5
.
•
STM PWB,
PL 70.28 Item 4
.
•
TTM PWB,
PL 70.90 Item 1
.
•
Drive PWB,
PL 1.10 Item 3
.
•
ESS PWB,