April 2017
2-444
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
041-334, 041-335
Launch Issue
Status Indicator RAPs
041-334 Drive PWB F11 Blown RAP
BSD-ON:
BSD 1.5 DC Power Generation (2 of 2)
BSD-ON:
BSD 1.7 Option DC Power Distribution
041-334 Drive PWB fuse 11 open circuit was detected.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Check the finisher for overcurrent and overvoltage. Repair the wiring or install new com-
ponents as necessary.
2.
After the faulty circuit has been repaired, install a new drive PWB,
PL 1.10 Item 3
.
041-335 Drive PWB F12 Blown RAP
BSD-ON:
BSD 1.5 DC Power Generation (2 of 2)
BSD-ON:
BSD 10.5 Fused Paper Exit 2
041-335 Drive PWB fuse 12 open circuit was detected.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Check the fuser exhaust fan for overcurrent and overvoltage. Repair the wiring or install
new components as necessary.
2.
After the faulty circuit has been repaired, install a new drive PWB,
PL 1.10 Item 3
.