PHASER 7300 CARE WORKSHEET
0
page 37
3.
Adjust the side 1 margins to the maximum negative value:
■
Use the
Up
and
Down Arrow
keys to scroll through the range of values, which is -40
to +40 units.
■
Set the value to -40, then press
OK
.
■
Select
Adjust Side 1 “B” Margin
, then press
OK
.
■
Record the value _________________________________.
■
Set the value to -40, then press
OK
.
■
Select
Print Calibrate Margins Page
, then press
OK
. The
Calibrate Margins Page
is generated. Using a pen or pencil, write “A & B Margins = -40” at the top of the page.
4.
Adjust the side 1 margin’s to the maximum positive value:
■
Select
Adjust Side 1 “A” Margin
, then press
OK
.
■
Set the value to +40, then press
OK
.
■
Select
Adjust Side 1 “B” Margin
, then press
OK
.
■
Set the value to +40, then press
OK
.
■
Select
Print Calibrate Margins Page
, then press
OK
. The
Calibrate Margins Page
is generated. Using a pen or pencil, write “A & B Margins = +40” at the top of
the page.
5.
Compare the original
Calibrate Margins Page
to the pages generated after changing
the Side 1 “A” and “B” margin values.
6.
Reset the Side 1 “A” and “B” Margin values back to those recorded in steps 2 and
3, respectively.
7.
Select
Print Calibrate Margins Page
, then press
OK
. The printed image should
return to its original location on the page.
8.
If a Duplex Unit is installed, follow the instructions on the
Calibrate Margins Page
to
view the effects of adjusting the Side 2 “A” and “B” Margins to their minimum and
maximum values. Upon completion, reset the values and reprint the
Calibrate Margins
Page
to verify proper adjustment.