Phaser 6115MFP Multifunction Product Service Manual
2-11
Theory of Operation
Fusing Temperatures by Media
During printing, the roller set temperature varies according to the media as
listed in the following tables:
* The temperature is controlled at 159 C if the system’s interior temperature is 20 ×C or
more and relative humidity is 40% or higher.
Note
There is a Control Panel command which obtains environmental
temperature and humidity levels. However, this command is for internal
use only and not available from the service menus.
If the print cycle is started while the Temperature/Humidity Sensor indicates
an internal temperature of 20 C or more, control is returned back to one
having a control temperature of more than 60 ×C after five printed pages have
been produced.
Fusing Temperatures for Monochrome
Media Type
Typical (°C)
Temperature/humidity
Sensor more than 20 °C
Plain paper, letterhead
169
174
Plain paper, letterhead 257 mm
or less
169
174
Thick stock, postcards, labels
169
Transparencies
169
Envelopes
194*
Glossy stock
169
Fusing Temperatures for Color (1-sided)
Media Type
Roller temp at
warm-up start
Typical (°C)
Temperature/
humidity
Sensor less
than 20 °C
Temperature/
humidity Sensor
more than 20 °C
Plain paper,
letterhead
60 C or less
189
194
189
More than 60 C
184
194
184
Plain paper,
letterhead 257
mm or less
60 C or less
189
194
189
More than 60 C
184
194
184
Thick stock,
postcards,
labels
_
184
Transparencies _
179
Envelopes
_
194*
Glossy stock
_
190
190
185
Summary of Contents for Phaser 6115 MFP
Page 1: ...Service Manual Phaser 6115MFP 701P28980 Color Laser Multifunction Product...
Page 2: ......
Page 44: ...1 22 Phaser 6115MFP Multifunction Product Service Manual General Information...
Page 144: ...3 42 Phaser 6115MFP Multifunction Product Service Manual Error Codes and Messages...
Page 270: ...7 16 Phaser 6115MFP Multifunction Product Service Manual Cleaning and Maintenance...
Page 530: ......
Page 531: ......
Page 532: ...701P28980...