background image

-1-

10/100 Fast Ethernet Managed

Switch with Fiber Connectivity

KS-801

Operation Manual

DOC.020419-KS801-K

Summary of Contents for KS-801

Page 1: ...1 10 100 Fast Ethernet Managed Switch with Fiber Connectivity KS 801 Operation Manual DOC 020419 KS801 K...

Page 2: ...nce Characteristics of Information Technology Equipment This device complies with CISPR Class A WARNING This is a Class A product In a domestic environment this product may cause radio inter ference i...

Page 3: ...ts 11 3 2 10 100BASE TX Fast Ethernet Ports 13 3 3 Fast Ethernet Fiber Slot 15 3 4 Making Trunk Connections 18 3 5 Making Sniffer 20 4 LED Indicators 21 4 1 LED Panels 21 4 2 Interpretation 21 5 Perfo...

Page 4: ...anagement 37 7 1 Start Browser Software and Making Connection 37 7 2 Login to the Switch 38 7 3 Port Status 40 7 4 Port Statistics 41 7 5 Administrator 42 7 5 1 Basic 43 IP Address 44 SNMP Entries 45...

Page 5: ...It also provides one Fast Ethernet Fiber slot for uplink to fiber backbone The key features of the switch units are Easy Migration With 10BASE T 100BASE T support the switch provides a non disruptive...

Page 6: ...lot supports 100BASE FX ST fiber module for MM fiber 100BASE FX SC fiber module for MM and SM fiber 100BASE FX MT RJ fiber module for MM and SM fiber 100BASE FX VF 45 fiber module for MM fiber Self le...

Page 7: ...le management via RS232 console port In band Telnet management over TCP IP network In band Web based management over TCP IP network In band SNMP management SNMPagentRFC1155 1157 MIB II private MIB SNM...

Page 8: ...Power status TPPortLED Link Activity Speed Duplex Collision status per port Filtering rate 14 880 pps for Ethernet 10BASE T 148 8 Kpps for Fast Ethernet 100BASE TX and FX Forwardingrate 14 880 pps fo...

Page 9: ...tries around the world Before connecting the supplied power cord into the switch check to see that the cord voltage and current rating conform to the standards of the country of operation 2 1 Packing...

Page 10: ...100 Port 1 9 10BASE T 100BASE TXPort 1 9 Crossover SW Crossover setting switch for 10 100 Port 9 100 Fiber Slot 100M Fiber slot for Port 9 LEDindicators LED display for power and all port status AC p...

Page 11: ...tion space between the switch and the objects around it DesktopMounting For mounting the switch into a 19 inch rack a pair of mounting brackets is included in the pack Install Rack Mount Brackets Inst...

Page 12: ...on types one is 10 100BASE TX RJ 45 connector and the other is 100BASE FX fiber slot The Fast Ethernet fiber slot can accommodate one optional Fast Ethernet fiber module The following table lists the...

Page 13: ...hrough UTP cable MDI RJ 45 connector is provided for easy uplink via standard straight through UTP to other device that supports MDI X RJ 45 connector The following table shows the pin assignments of...

Page 14: ...g to a non auto negotiation device half duplex mode is used However the ports can auto detect the connection speed ManualConfiguration The ports are configured to be enabled for auto negotiation as fa...

Page 15: ...ing straight through UTP cable make sure MDI X to MDI connection rule is followed The following figure illustrates the pin assignments of a straight through UTP and a crossover UTP cable Straight thro...

Page 16: ...m length 800 T ST MM 2 Km 800 C SC MM 2 Km 800 SA SC SM 15 Km 800 S3 SC SM 30 Km 800 S5 SC SM 50 Km 800 JM MT RJ MM 2 Km 800 JS MT RJ SM 15 Km 800 VM VF 45 MM 2 Km MM Multimode fiber cable SM Single m...

Page 17: ...odules Different type of modules is mounted with different fiber connector FiberModule Topview Fiber Jumper Setting The jumper group J1 on the module is used to enable or disable the fiber module The...

Page 18: ...X Speed 100Mbps Duplex mode Full duplex or half duplex Wavelength 1300nm Fiber Connectors ST SC MT RJ VF 45 Fiber cable MM 50 125mm 62 5 125mm recommended SM 9 125mm recommended ModuleInstallation 1 T...

Page 19: ...n be configured optionally as trunking ports through the network management operation Two trunking ports composes one trunk Two switch units can be cascaded through one trunk The aggregated bandwidth...

Page 20: ...2 One trunking port can only belong to one trunk 3 Only one trunk can exist between two switch units 4 Crossover UTP cables should be used at the same time for one trunk connection The length of each...

Page 21: ...for monitor traffic in switched networks Any switched port can be defined as a sniffer port which can monitor one or more port traffic Normally it is connected to a LAN analyzer equipment When doing s...

Page 22: ...LED indicate the duplex mode used and collision status FX LED indicate the fiber module is installed and active The LED indicators labeled a port number on top are corresponding to a specific 10 100B...

Page 23: ...ons and can be managed by using the following methods Direct console connection over an RS232 cable Web browser software from Internet or Intranet over TCP IP network Telnet software over TCP IP netwo...

Page 24: ...e good bad drop packet counts Administrator Basic Management IP address settings SNMP settings Advanced Management Spanning tree protocol settings Trunking settings Sniffer settings Console Port Infor...

Page 25: ...sole management before performing any in band management operation When you log on to the switch console port for the first time a sign on string appears and you are prompted for a console login name...

Page 26: ...Microsoft Internet Explorer 4 0 or later on any platform Con nect to the managed unit using the IP address as URL address http xxx xxx xxx xxx Refer to Chapter 7 for more information 5 6 Telnet Manage...

Page 27: ...ned in the standard MIB II and private MIB The supported MIBs are available in the supplied CD ROM of the switch Use the SNMP management application software to compile the MIB file first before perfo...

Page 28: ...gin admin password Welcome admin INET Factory default Username admin Factory default Password 123 The main menu is shown as follows Management Switching Hub Setup Menu TCP IP stack for ARM vx xx 1 Set...

Page 29: ...y IP xxx xxx xxx xxx WARNING change ip will kill all current net connec tion IPAddress Unique IP address designated to this switch Subnet Mask the subnet mask of the IP address specified above Gateway...

Page 30: ...100 Full Enable 6 Unlink Disable 100 Full Enable 7 Unlink Disable 100 Full Enable 8 Unlink Disable 100 Full Enable 9 Unlink Disable 100 Full Enable The port status definitions are Port Status States...

Page 31: ...000000 5 000000 000000 000000 000000 000000 000000 6 000000 000000 000000 000000 000000 000000 7 000000 000000 000000 000000 000000 000000 8 000003 000000 000000 000136 000000 000000 9 000000 000000 0...

Page 32: ...osts to determine which port to select as a forwarding port You should assign lower numbers to ports attached to faster media such as full duplex and higher numbers to ports attached to slower media T...

Page 33: ...a is not transmitted Learning The switch enters the Learning State if no path with a higher priority is found during the Listening State Learned entries are entered in the Unicast Destination Forwardi...

Page 34: ...Address 192 168 0 5 Subnet Mask 255 255 255 0 Default Gateway 192 168 0 254 Spanning tree Disabled Trunking Disabled Sniffering Disabled Port Control Enabled Speed Auto Duplex Auto Flow Control Enable...

Page 35: ...d select Update Firmware command from the main menu of console management screen When Waiting message is shown on screen to indicate the switch is ready to receive file from console port 3 Execute the...

Page 36: ...ecute the utility program SFTP EXE from your DOS window The command syntax is C WINDOWS SFTP n filename Enter n 1 COM1 2 COM2 filename the file name of the new firmware The prompts shown on DOS screen...

Page 37: ...date data size is xxxxx Programming finished 5 When finishing the download reboot the switch to make the update effect 6 8 Remote Boot System Select 8 from Setup menu to reboot the system This reboot...

Page 38: ...t IP Address for the Switch Before the switch can be managed from a web browser software make sure a unique IP address is configured to the switch Refer to Console Management for how to set IP address...

Page 39: ...gin to the Switch When browser software connects to the switch successfully a Login screen is provided for you to login to the switch as follows Login Factory default Username Admin Factory default Pa...

Page 40: ...n is performed In addition to the device image the screen supports the following func tions on left side 1 Home home page and device image 2 Port Status view all port status 3 Port Statistics view all...

Page 41: ...rma tion includes Port No LAN Port number Link Status Up link is active Down no link Port Control Port function is enabled or disabled Speed Status Connection speed used on the port Duplex Status Dupl...

Page 42: ...lly Send Bad number of packets transmitted unsuccessfully Send Abort number of packets aborted when transmission Receive Good number of packets received successfully Receive Bad number of packets rece...

Page 43: ...43 7 5 Administrator Click Administrator to perform more management functions as follows Basic Advanced Console Port Information Port Controls Security Manager System Manager...

Page 44: ...44 7 5 1 Basic Click Basic to view or modify the following settings IP Address SNMP Entries...

Page 45: ...s of this switch Subnet Mask the subnet mask of the IP address specified above Gateway the IP address of default gateway router Click Apply to make the change effective immediately If you change the I...

Page 46: ...46 SNMP Entries Use scroll bar to view all settings as follows...

Page 47: ...act person Community string list list of authorized SNMP communities Trap Manager list list of SNMP trap managers Only SNMP managers who are in the Community list can access this device with the autho...

Page 48: ...48 7 5 2 Advanced Click Advanced inmenutoperform Spanning Spanning Tree protocol settings Trunking Trunking settings Sniffer Sniffer settings...

Page 49: ...the forwarding algorithm and allows duplicate frames to be forwarded To provide path redundancy Spanning Tree Protocol defines a tree that spans all switches in an extended network Spanning Tree Prot...

Page 50: ...50...

Page 51: ...51...

Page 52: ...sest to the Root Switch Only one port on each switch is assigned as the Root Port Max Age Maximum Age Timer measures the age of the received protocol information recorded for a port and ensures that t...

Page 53: ...e same priority value the lowest port number forwards the spanning tree frames Port Status Ports which are enabled can be in one of the follow ing states Listening Switches send messages to one anothe...

Page 54: ...king ports Select one configuration from the following four options None No trunking Port 1 2 Use port 1 and port 2 to compose one trunk Port 7 8 Use port 7 and port 8 to compose one trunk Port 1 2 7...

Page 55: ...list and one sniffer port Select one or more LAN ports into the monitored port list All port traffic of monitored ports will be forwarded to a designated sniffer port at the same time when the traffic...

Page 56: ...switched port as a sniffer port Sniffer port can receive all port traffic forwarded from all monitored ports The sniffer port can not be one of the members of monitored port list Click Update to chang...

Page 57: ...57 7 5 3 Console Port Information Click Console Port Information from Administrator sub menu to view console port information They are BaudRate Bit sec Data Bits Parity Check Stop Bits Flow Control...

Page 58: ...to configure LAN ports The con figuration options are Port Control Enable Disable Speed Setting Auto 100M 10M Duplex Setting Auto Full Half Flow Control Setting Enable Disable Note Port Control enable...

Page 59: ...59 7 5 5 Security Manager Click Security Manager to view or change user name and password...

Page 60: ...60 7 5 6 System Manager Click System Manager to perform TFTP Update Firmware Remote Boot System...

Page 61: ...and in stalled in the network to support the file transfer with the switch Specify the following information for TFTP operations TFTP Server IP Address IP address of the TFTP server where the firmware...

Page 62: ...rmware to confirm update to the switch A reboot screen shows up afterward to request for a reboot operation Refer to next sec tion for more information The updated firmware file can be obtained from v...

Page 63: ...63 Remote Boot System After a firmware upgrade you must reboot the switch to start new firm ware Click Reboot to reboot the switch...

Reviews: