Installation Preparation Document
(for physical installation of the product only)
Xerox DocuTech 6155/6180
701P43858
June 2005
Please ensure electrical, space, and supplies are available prior to equipment delivery
.
Customer Support
The Xerox Customer Support Center is available to provide general
information, answer questions, and take service calls. You can reach
the Customer Support Center at the following toll-free phone number:
United States
1-800-821-2797
Your Xerox Analyst will provide fee-based training upon request.
Space Requirements / Service Envelope
The components of the DocuTech 6180 system are:
•
DocuSP Controller (monitor, keyboard, mouse)
•
Printer
WIDTH
DocuTech 61xx
Representation only.
D
E
P
T
H
Note: The 6155 and 6180 are available with and without a stand to
support the controller. If a stand (098S04797) is ordered, it will be
positioned to the left of the printer, within the service space envelope.
If no stand is ordered, the controller will be placed on the floor to the
left of the printer in the service space envelope.
Note: The dimensions shown below provide the overall service
space required, including the space to the nearest obstruction. The
dimensions are in
inches
and are absolute minimums
With stand
Without stand
Configuration
Width Depth Width Depth
6155, 6180 with
interposer and
finisher
243.0" 114.0” 240.0” 114.0"
Electrical Requirements – DocuTech 6155 / 6180
For the printer one (1) electrical service option is available – 2-phase,
dual power cord.
MultiSource
2-phase, dual power cord
configuration
Voltage 208/240
(4 wire)
208/240
(4 wire)
Amperage 50
30
Cycles
60 Hz
60 Hz
Receptacle Xerox Part No.
600S3779
600S3277
Receptacle NEMA Part No.
14-50R
14-30R
Receptacle Diagram
Power Cord Kit Number
98K59581
Power Cord Length
15 feet
15 feet
Electrical Requirements
Digital Front End (DFE) Controller Platform:
Line Options:
Dedicated
Voltage 110
Amperage 15
Cycles 60
Hz
15 amp Receptacle Xerox Part No.
20 amp Receptacle Xerox Part No.
600S3704
600S3703
Receptacle NEMA Part No.
5 - 20R or 5 - 15R
Receptacle Diagram
or
•
All controller configurations require a 110VAC, 15 Amp
grounded receptacle for the outlet strip that provides
receptacles
for the
controller and its peripheral devices (monitor, modem,
CDROM drive, and tape drive)
•
Adapters that eliminate the ground connection to the outlet can
not be used.
•
Xerox provides 15 feet of cabling with Teflon coating (Plenum
rated), to connect the controller to the Processor/Finisher.
Environmental Requirements
Recommended Min.
Max.
Temperature
68
o
F – 76
o
F
(20
o
C-24
o
C)
50
o
F
(10
o
C)
85
o
F*
(29
o
C)
Humidity
45% +/-10%
30% RH
60% RH
Heat Emission –
with Binder On
(with processor,
interposer, finisher
and binder)
- 14,185
BTU/Hr
(with vent kit)
22,165
BTU/Hr
(Running)
Heat Emission –
with Binder Off
(with processor,
interposer, finisher
and binder)
- 13,609
BTU/Hr
(with vent kit)
21,265
BTU/Hr
(Running)
Altitude (above
sea level)
Up to 6,000 ft.
-
9,000 ft.
* The system will inhibit software problems and shut down above 90
o
F