background image

Installation Preparation Document 

(for physical installation of the product only)

 

 

Xerox DocuTech 6155/6180

 

 

 

701P43858 
June 2005 

Please ensure electrical, space, and supplies are available prior to equipment delivery

.

 

Customer Support 

The Xerox Customer Support Center is available to provide general 
information, answer questions, and take service calls. You can reach 
the Customer Support Center at the following toll-free phone number: 

United States 

1-800-821-2797 

Your Xerox Analyst will provide fee-based training upon request. 

 

Space Requirements / Service Envelope

 

The components of the DocuTech 6180 system are: 

• 

DocuSP Controller (monitor, keyboard, mouse) 

• 

Printer 

WIDTH

DocuTech 61xx

Representation only.

D

E

P

T

H

 

 
Note: The 6155 and 6180 are available with and without a stand to 
support the controller.  If a stand (098S04797) is ordered, it will be 
positioned to the left of the printer, within the service space envelope. 
If no stand is ordered, the controller will be placed on the floor to the 
left of the printer in the service space envelope.  
Note:  The dimensions shown below provide the overall service 
space required, including the space to the nearest obstruction.  The 
dimensions are in

 

inches

 and are absolute minimums 

 

 

With stand

Without stand

Configuration 

Width Depth Width Depth 

6155, 6180 with 
interposer and 
finisher 

243.0" 114.0”  240.0” 114.0" 

 

Electrical Requirements – DocuTech 6155 / 6180 

For the printer one (1) electrical service option is available – 2-phase, 
dual power cord. 

 

 

MultiSource 

2-phase, dual power cord 

configuration 

Voltage 208/240

(4 wire)

 208/240 

(4 wire)

 

Amperage 50 

30 

Cycles 

60 Hz 

60 Hz 

Receptacle Xerox Part No. 

600S3779 

600S3277 

Receptacle NEMA Part No. 

14-50R 

14-30R 

Receptacle Diagram 

 

 

Power Cord Kit Number 

98K59581 

 

Power Cord Length 

15 feet 

15 feet 

 

Electrical Requirements 

Digital Front End (DFE) Controller Platform:

 

Line Options: 

Dedicated 

Voltage 110 

Amperage 15 

Cycles 60 

Hz 

15 amp Receptacle Xerox Part No. 
20 amp Receptacle Xerox Part No. 

600S3704 
600S3703 

Receptacle NEMA Part No. 

5 - 20R or 5 - 15R 

Receptacle Diagram 

 or 

 

 

• 

All controller configurations require a 110VAC, 15 Amp 
grounded receptacle for the outlet strip that provides

 receptacles 

for the 

controller and its peripheral devices (monitor, modem, 

CDROM drive, and tape drive) 

• 

Adapters that eliminate the ground connection to the outlet can 
not be used

• 

Xerox provides 15 feet of cabling with Teflon coating (Plenum 
rated), to connect the controller to the Processor/Finisher. 

 

Environmental Requirements  

 

 

Recommended Min. 

Max. 

Temperature  

68

o

 F – 76

o

(20

o

 C-24

o

 C)

 

50 

o

 F     

(10

o

 C)

 

85

o

 F* 

(29

o

 C)

 

Humidity 

45% +/-10% 

30% RH 

60%  RH 

Heat Emission – 
with Binder On 

(with processor, 
interposer, finisher 
and binder) 

- 14,185 

BTU/Hr  

(with vent kit)

 

22,165 

BTU/Hr 

(Running) 

Heat Emission – 
with Binder Off 

(with processor, 
interposer, finisher 
and binder) 

- 13,609 

BTU/Hr  

(with vent kit)

 

21,265 

BTU/Hr 

(Running) 

Altitude (above 
sea level) 

Up to 6,000 ft. 

9,000 ft. 

* The system will inhibit software problems and shut down above 90 

o

 F 

Reviews: