Installation Preparation Document 

(for physical installation of the product only)

 

 

Xerox DocuTech 6100/6115/6135

 

 

 

701P43857 

June 2005

 

Please ensure electrical, space, and supplies are available prior to equipment delivery

.

 

Customer Support 

The Xerox Customer Support Center is available to provide general 
information, answer questions, and take service calls. You can reach 
the Customer Support Center at the following toll-free phone number: 

United States 

1-800-821-2797 

Your Xerox Analyst will provide fee-based training upon request. 

 

Space Requirements

 

The diagram below is provided as a representation only of the space 
envelope required for installation of Xerox equipment.  Diagram is a 
representation only and not drawn to scale. 

 

W ID T H

 

D o c u T e c h   6 1 x x

 

R e p r e s e n t a t io n   o n ly .

D

E

P

T

H

 

Note: The 6100, 6115, 6135 are available with and without a stand to 
support the controller.  If a stand is ordered, it will be positioned to the 
left of the printer, within the service space envelope. If no stand is 
ordered, the controller will be placed on the floor to the left of the 
printer in the service space envelope.  
Note: The dimensions shown below provide the overall service space 
required, including the space to the nearest obstruction.  The 
dimensions are in

 

inches

 and are absolute minimums. 

 

 

With stand

Without stand

Configuration 

Width Depth Width Depth 

6100, 6115, 6135 
with interposer, and 
Finisher 

243.0" 114.0”  240.0” 114.0" 

6100, 6115, 6135 
without Interposer, 
with Finisher  

196.0" 114.0” 193.0”  114.0" 

 

Electrical Requirements

 

Printer/Finisher/Binder

 

Line Options:

 

Single 

Source

 

Voltage 208/240 

Amperage 50 

Cycles 60 

Hz 

Receptacle Xerox Part  No. 

600S3779 

Receptacle NEMA Part No. 

14-50R 

Power Cord Xerox Part No. 

98K19950 

117K9940 

Receptacle Diagram

 

 

* D

edicated power outlets required.  Ensure each power cord has a separate 

circuit that cannot be shared with other devices.

 

*15 ft. power cord(s) are provided, however, the distance from the equipment 
to the outlet should not exceed 13.1 ft.   

  

 

Electrical Requirements 

Digital Front End (DFE) Controller Platform:

 

Line Options: 

Dedicated 

Voltage 110V 

Amperage 15 

Cycles 60 

Hz 

15 amp Receptacle Xerox Part No. 
20 amp Receptacle Xerox Part No. 

600S3704 
600S3703 

Receptacle NEMA Part No. 

5 - 20R or 5 - 15R 

Receptacle Diagram 

 or 

 

• 

All controller configurations require a 110VAC, 15 Amp 
grounded receptacle for the outlet strip that provides

 receptacles 

for the 

controller and its peripheral devices (monitor, modem, 

CDROM drive, and tape drive) 

• 

Adapters that eliminate the ground connection to the outlet can 
not be used

• 

Xerox provides 15 feet of cabling with Teflon coating (Plenum 
rated), to connect the controller to the Processor/Finisher. 

 

Interposer 

Line Options: 

Dedicated 

Voltage 120 

Amperage 15 

Cycles 60 

Hz 

Receptacle Xerox Part No. 

600S3704 

Receptacle NEMA Part No. 

5 - 15R 

Power Cord Length 

6 feet 

Receptacle Diagram 

 

 

Installation Considerations

 

• 

There should be a minimum of 78 inches (1,981mm) clearance 
from the floor to the nearest overhead obstruction.

 

• 

Mobility Assist Device  - The optional mobility assist device 
reduces the installation clearance required to 30

 

inches

 

(760mm) at the processor end of the printer and 15 inches (380 
mm) at the finisher end.

 

• 

For proper operation, the printer must be perfectly level. The 
floor must be level within 2 degrees in any direction. On floors 
less than 2 degrees out of level, installation personnel install a 
leveling kit to level the machine. 

• 

If the floor is more than 2 degrees out of level, this condition 
cannot be corrected by the leveling kit. Another suitable location 
must be found for the printer to be installed properly. 

• 

A minimum 50-inch clearance of exclusive operator area must 
be maintained in front of each component.  This space cannot 
be shared. 

• 

A minimum of 36 inches of clearance is required in the back of 
each component for general service clearance. 