Component Control Output Tests
Component Control Output tests are used to aid in verifying proper component operation
and identifying problems and isolating faulty components. To access the following tests,
you must enter Diagnostics Mode:
1.
Enter Diagnostics Mode - press and hold [2] and [6] while powering up the printer.
Continue holding [2] and [6] until *IOT?* is displayed.
2.
Release [2] and [6], then press and hold [4] until “Main Menu” appears in the top line
of the display. You are now in Diagnostics Mode.
3.
Use the Control Panel Test Legend below to help navigate throught the various items in
the Component Control Output table.
4.
Press [1] or [5] until “Main Menu Comp Output Test” is displayed.
5.
Follow the table headings, and the Control Panel Test Legend below, to navigate to the
desired test.
The tests in the table below enable the technician to test the many output
devices performing work inside the printer.
Control Panel Test Legend:
Nomenclature Legend:
IOT
: Print Engine - the printer not including the
System Controller Board or options.
HCF
: High Capacity Feeder Option
MBF (or MSI)
: Multi-sheet Bypass Feeder
ENV
: Envelope Feeder Option
Fin
: Finisher Option
Table 1-107 Component Control Output
Press [1] or [5] to display: Main Menu
Comp Output Test
Press [2] or [6] to
display:
ß
Press [3] or [7] to
display:
ß
Turn -On
Duration
Comment
Comp Output Test
IOT Unit
Main Motor On
2 min.
Press [4] to start test.
Actuate Main Drive Motor for duration or
Press [0] to stop.
Fuser Fan High
2 min.
Press [4] to start test.
Actuate Fuser Fan for duration or
Press [0] to stop.
LVPS Fan High
2 min.
Press [4] to start test.
Actuate Low Voltage Power Supply fan for
duration or Press [0] to stop.
ROS Motor On
2 min.
Press [4] to start test.
Actuate Laser Scanner Motor for duration or
Press [0] to stop.
ROS Motor Stadby
2 min.
Press [4] to start test.
Places Laser Scanner Motor in standby for
duration or Press [0] to stop.
Tray 1 Lift Mot
2 sec.
Press [4] to start test.
Actuate Tray 1 Lift Motor for duration or
Press [0] to stop.
Stop
Start
Menu Up
Item Up
Value Up
Menu
Down
Item
Down
Value
Down