background image

DocuColor 6060/7000/8000 Digital Color Press

Charge Corotron Cleaning Procedure

701P46606, Version 1.0, February 2007

1

IMPORTANT!!

This procedure is available for downloading at 

www.xerox.com

:

Click the 

Support and Drivers

 link.

In 

Product Name

, type the desired product 

name (6060, 7000, or 8000), and click 

Search

.

From the list presented, locate the correct 

product, and click the Download, or 

Documen-

tation

 link.

From the User Documenation list, select Docu-

Color 6060/7000/8000 Charge Corotron 

Cleaning Procedure.

Cleaning the Charge Corotrons

The DocuColor 6060 now uses a new Charge 

Corotron Assembly. For DocuColor 7000/8000 

customers, the assembly is the same, but the part 

number is new:

The new Charge Corotron Assembly part 
number for DocuColor 6060/7000/8000 is 

13R629

.

Each corotron assembly is equipped with a 

cleaning pad and a cleaning wand which makes it 

very easy to clean the corotron. The cleaning pad 

and wand are components of the Corotron 

Assembly; they are not separate parts.

Tip:

Each corotron unit should be cleaned one 

time daily in order to provide optimum image 

quality on your prints. It is recommended that you 

perform this procedure at the start of every day and 

after every 5,000 prints.
Use the following procedure for daily cleaning of 

the charge corotrons.
1. Open the front doors of the digital press.
2. Clean each corotron by 

slowly

 pulling out and 

pushing in the Cleaning Wand one time.

Tip:

To ensure proper cleaning of the pad, 

slowly

 

pull out the wand 

until it reaches the end of the 

assembly

it will stop when it reaches the 

end

. Slowly push in the wand until it is fully seated 

against the corotron assembly.

CAUTION:

To avoid damage to the corotron 

assembly, 

carefully

 and 

slowly

 pull out the 

Cleaning Wand. Once the wand reaches the end of 

the assembly, it stops. Do not continue to pull on 

the wand as this will remove the wand from the 

Corotron Assembly, thereby damaging the 

assembly. If this occurs, you must replace the 

entire Corotron Assembly.
3. Ensure that the Cleaning Wand is pushed in 

completely.

Verify that both the corotron assembly and 

the cleaning wand are seated properly. If 

either one is not seated properly, the User 

Interface displays a screen with the 

message: “

Reseat the Charge Corotron 

Unit

.”

Select 

Close

 on the UI.

Repeat Steps 2 and 3.

Cleaning Pad

Corotron Assembly

Cleaning 

Wand

Slowly

 pull out the wand, 

then push it back in

Reviews: