Using AutoCal and ColorCal
10.
Place the Gray Scale strip, Color Scale strip, and scanner measurement page in the
correct positions on the copier glass for scanner calibration.
Place the Gray Scale face down on the copier glass so that it will be centered along the
top edge of the scanner measurement page. Then place the Color Scale strip face down
on the copier glass so it is centered below the Gray Scale strip, keeping a distance of
0.25 inch to 0.5 inch between the two strips. Finally, place the scanner measurement
page face down over the strips.
To perform the scanner calibration, click Continue in the dialog box that appears.
After the scanner has been calibrated, another dialog box appears, prompting you to
calibrate the Fiery.
11.
Follow the directions in the dialog box for placing the Gray Scale strip and the AutoCal
or ColorCal measurement page on the copier glass. Click Continue to perform the Fiery
calibration.
12.
Click Apply in the main Calibrator window to implement the new calibration set.
13.
Click OK in the Information dialog box.
This completes the calibration process.
AutoCal
ColorCal