4 - 11
Presentation Sensitivity
Presentation Sensitivity is a numeric range that increases or decreases the
scanner's reaction time to bar code presentation. To set the sensitivity,
scan the
Sensitivity
bar code, then scan the degree of sensitivity (from 0-
20) from the inside back cover, and
Save
. 0 is the most sensitive setting,
and 20 is the least sensitive.
Default = 1.
Presentation Centering
Use Presentation Centering to narrow the scanner’s field of view when it is
in the stand to make sure the scanner reads only those bar codes intended
by the user. For instance, if multiple codes are placed closely together,
Presentation Centering will insure that only the desired codes are read.
Note: To adjust centering when the scanner is hand-held, see
If a bar code is not touched by a predefined window, it will not be decoded
or output by the scanner. If Presentation Centering is turned on by scan-
ning
Presentation Centering
On
, the scanner only reads codes that pass
through the centering window you specify using the
Top of Presentation
Centering Window, Bottom of Presentation Centering Window, Left
,
and
Right of Presentation Centering Window
bar codes.
Sensitivity
Summary of Contents for 1900
Page 1: ...Xenon 1900 1910 Xenon 1902 1912 Granit 1910i 1911i Area Imaging Scanner User s Guide...
Page 20: ......
Page 32: ...xii...
Page 72: ...2 24 1200 2400 4800 9600 19200 38400 57 600 115 200...
Page 118: ...3 40...
Page 148: ...4 30...
Page 174: ...6 20...
Page 238: ...7 64...
Page 258: ...8 20...
Page 262: ...9 4...
Page 268: ...10 6...
Page 312: ...11 44...
Page 350: ...A 14...
Page 353: ...Sample Symbols Aztec MaxiCode Micro PDF417 Package Label Test Message Test Message...