background image

UES Series Solar Charge Controller

User’s Manual

1. Product Introduction

UES series solar charge controller is a kind of intelligent, multi-functional solar charge and discharge

controller. These serial products adopt customized LCD display screen, which makes the operation on the interface rather
convenient. All the controlling parameters can be reset flexibly to satisfy your different needs.

This controller has the following features:

2. Specification

Model

UES-2410

UES-2420

Max. charge current

10A

20A

Max. discharge current

10A

20A

Max. solar panel input voltage

≤55V

Rated voltage

12V/24V auto work

Stop charge voltage

14.7V/29.4V

Low voltage recovery

12.2V/24.4V

Low voltage protection

10.5V/21.0V

USB output voltage/current

5V 2A

Characteristic

No load loss:≤10mA; Temperature compensation:-3mV/cell/

Operation temperature

-20

~60

Dimension of controller

152×80.2×30mm (L*W*H)

Package size

163×95×40mm (L*W*H)

Weight

200g

*Parameters may customized by customers.

● Visual LCD graphic symbol

● Brief key operation

● Automatic identification system voltage level

● Intelligent PWM charge mode

● Automatic temperature compensation

● Multiple selection of battery

● Adjustable charge-discharge control parameters

● Settable operating modes of loads

●Accumulated function of charge and discharge ampere hours

● Battery over temperature protection

● Battery low voltage protection

● Battery reverses polarity protection

● Overload & short circuit protection

● With Dual USB 5V output

Summary of Contents for UES-2410

Page 1: ...14 7V 29 4V Low voltage recovery 12 2V 24 4V Low voltage protection 10 5V 21 0V USB output voltage current 5V 2A Characteristic No load loss 10mA Temperature compensation 3mV cell Operation temperature 20 60 Dimension of controller 152 80 2 30mm L W H Package size 163 95 40mm L W H Weight 200g Parameters may customized by customers Visual LCD graphic symbol Brief key operation Automatic identifica...

Page 2: ...arameters minus button load output switch Parameters Display As shown in the installation connection diagram the battery solar panel load and controller should be connected by turns Please connect the battery first and then the solar panel or load Pay attention that the positive and negative polarity are consistent with the controller ...

Page 3: ...rface keep pressing the button for 5 seconds the figure flickers it means the controller enters into the setting mode At this time you can press the button to adjust the parameters After finish setting the parameters shortly press the button and the controller will save the set parameters automatically At this interface when there is no operation for 20 seconds it will automatically exit the setti...

Page 4: ...en the system return to normal work Over temperature protection when the temperature of the controller higher than 70 the charge and discharge of the controller stop working When the temperature of the controller less than 65 the controller returns to the previous working state GUARANTEE Customer Name Telephone Model E mail Bar Code No Purchase Area Address After Sales Service 1 After the product ...