Features: 

) Connect up to 32 Targets. 

) Target Auto up/ down without connect Control unit. 

) Magnet drive Target up/ down (Pattern: ). 

) Standard (EIA 568B) cable connect (RJ45 Cable same as PC Cable). 

) Control unit (option),there are 4 games and operation setting. 

) LED Display 64*16cm (option). 

) Start Switch  (option). 

XCORTECH 

XTS105 Auto Target System  

For Target System connect without Control unit

 

Summary of Contents for XTS105

Page 1: ...Magnet drive Target up down Pattern Standard EIA 568B cable connect RJ45 Cable same as PC Cable Control unit option there are 4 games and operation setting LED Display 64 16cm option Start Switch option XCORTECH XTS105 Auto Target System For Target System connect without Control unit ...

Page 2: ...stem Max 2 M cable length between targets or need to add PDU Max 20 M for total cable length or need to add PDU Power Input for Target system DC 9 24V Suggestion DC 24V 5A for 12 targets If end of Targets not go up at the same time that maybe low power supply need to add PDU and Power PDU Power Distribution Unit XCORTECH XTS105 Auto Target System 12 Target System connection ...

Page 3: ...Pass ERR1 No Response Ex LED board Disconnect ERR2 Unknown Device COMM Targets Communication status PASS Total Targets communication Pass ERR1 one or more targets communication error Ex Disconnect target cable ERR2 Unknown Device Ex Add new Target s Error3 No Any Targets Solve To do Auto Address again XCORTECH XTS105 Auto Target System For Target System connect with Control unit TARGET SYSTEM XTS1...

Page 4: ...s MISS Miss total green target BAD Hit red targets SCORE Total 1000 EX If 12 Targets in the system RN Round 2 H Hostage 4 Total raise targets is 36 3 12 Green target raise 24 4 20 Hit Hit a green target 1000 20 50 score Miss Miss a green target 1000 20 50 score Bad Hit a red target 50 2 100 score EX Hit 9 green targets Hit a red target Miss Miss 11 20 9 Total score 50x9 100x1 50x11 200 分 LV LEVEL ...

Page 5: ... system have 12 targets Set ROUND 2 That will raise 12x2 24 targets LEVEL Lower level is easy mode Bigger level is difficult mode WHACK A MOLE LEVEL 1 ROUND 3 WHACK A MOLE RESCUE LEVEL 1 ROUND 3 HOSTAGE 2 RESCUE Shoot green target Don t shoot the red target COMPETE LEVEL 1 ROUND 3 COMPETE Only raise a target for each time XCORTECH XTS105 Auto Target System For Target System connect with Control un...

Page 6: ...CH XTS105 Auto Target System For Target System connect with Control unit Auto Target system install instruction Controller need to connect to last unit from power PDU need to connect to Target and LED Display ...

Page 7: ...m Operation instruction Quick Strat YouTube Search XTS105 Xcortech XTS105 Auto target install 1 https youtu be hamUhHuvyRs Xcortech XTS105 Auto target setup 2 https youtu be s3Ha9wz_rQI Xcortech XTS105 Auto Target Game Operation 3 https youtu be anScjxY2FXg Manual Download http www xcortech com tw ...