![Xantrex XPower Inverter 3000 Installation Manual Download Page 17](http://html1.mh-extra.com/html/xantrex/xpower-inverter-3000/xpower-inverter-3000_installation-manual_3430891017.webp)
Selecting Cable Sizes
975-0556-01-01
17
Mounting Dimensions
Use the measurements below to plot the holes in the surface
where you want to anchor the XPower inverter and permanently
mount it into place.
Figure 4 Mounting Dimensions (Not to scale)
450 mm (17.7 in.)
225 mm
(8.9 in.)
91.5 mm
(3.6 in.)
mounting hole Ø 5 mm (0.2 in.)
126.5 mm
(5 in.)
Selecting Cable Sizes
To operate safely and effectively, the XPower Inverter 3000 needs
proper cables and fuses. The XPower inverter has low-voltage
and high-current input, so it is essential that you use low-
resistance wiring between the battery and the inverter. This
means using the largest gauge and shortest DC cables. The goal
is to deliver the maximum amount of usable energy to your load.
For safe and efficient operation, you will need to calculate cable
sizes for your:
n
DC input cables from the battery to XPower inverter, and
n
Chassis ground cable from the vehicle chassis to the
chassis ground lug on the XPower inverter’s DC panel.
WARNING
FIRE HAZARD
Use only copper wire rated 75 °C minimum. Never use a DC
input cable longer than specified in “DC Input Cables” below. A
longer cable can potentially generate enough heat to start a fire
or result in poor XPower inverter performance.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
Summary of Contents for XPower Inverter 3000
Page 1: ...XPower Inverter 3000 Installation Guide XPower 3000 813 3000 UL...
Page 10: ...This page is intentionally left blank...
Page 30: ...975 0556 01 01 Rev A http www xantrex com 1 800 670 0707 1 408 987 6030 Printed in...
Page 31: ...Onduleur 3000 XPower Guide d installation XPower 3000 813 3000 UL...
Page 62: ...975 0556 02 01 Rev A http www xantrex com 1 800 670 0707 1 408 987 6030 Printed in...