Warning Messages
46
Freedom HF Owner's Guide
Error Code
Condition
Mode
Action
E01
Low battery voltage shutdown is
imminent depending on the
setting, see
.
Inverting
Check battery status and recharge if necessary.
Check for proper DC cable sizing.
Check for loose connections and tighten if necessary.
E02
High battery voltage shutdown
> 15.5 volts DC
Inverting
Check for external charging sources, such as a PV charger and an over
voltage alternator. Disconnect, if necessary.
E03
AC output overload shutdown
Inverting
Reduce the loads connected to the AC outlet of the unit.
Check appliances that have high-surge ratings and disconnect if necessary.
E04
Over-temperature shutdown
Inverting
Reduce the loads connected to the AC outlet of the unit.
Check that the ventilation grille is not blocked.
Check for ambient temperature and move the unit to a cooler location
whenever possible.
E05
Low battery voltage detected
depending on setting, see
Inverting
Check battery status and recharge if necessary.
Check for proper DC cable sizing.
Check for loose connections and tighten if necessary.
E06
AC output overload warning
Inverting
Reduce the loads connected to the AC outlet of the unit.
E07
Over-temperature warning
Inverting
Reduce the loads connected to the AC outlet of the unit.
Check that the ventilation grille is not blocked.
Check for ambient temperature and move the unit to a cooler location
whenever possible.
E08
not used
E09
not used
Table 6 Error codes displayed on the Display Panel screen