Solar Panel Wiring
a.
Depending on your power needs and installation type, you have two kinds of solar charge
controllers available.
Solar Charge Controller
Amp
Output Voltage
Part Number
Pulse width modulation
30A
12/24VDC
709-3024-01
Maximum power point tracking
30A
12/24VDC
710-3024-01
b.
Solar panels can be configured in series, parallel, or a combination of both series and parallel.
Figure 5 Cable schematic for series
Pos (+) of first panel connects to Neg (-) of next panel and so on and terminating with the Pos (+)
of the solar charge controller.
Neg (-) of first panel extends to Neg (-) terminal of the solar charge controller.
Optimized for MPPT solar charger.
11
975-1029-01-01 Rev E
February 2024