INSTALLATION INSTRUCTIONS 

 
DESCRIPTION 

The Hidden Link IR Receiver is a small shelf-top infrared repeater assembly. 
It includes an IR receiver and a CB12 Connecting Block. The Hidden Link IR 
Receiver is equipped with a 7-foot cable and a 3.5mm stereo mini plug, 
which is plugged directly into the “IR RCVR” jack on the CB12. It can also be 
plugged into the “AUX” or “IR RCVR” jack of other Xantech connecting 
blocks, such as the models 789-44, CB60, and 791-44. The Hidden Link IR 
Receiver is primarily intended for use in installations where the connecting 
block is within reach of its 7-foot cable – as when installing the Hidden Link 
IR Receiver in a cabinet where the controlled equipment is behind closed 
doors.  
 

FEATURES 

 

Very small package, only 2.00”L x 3.15”W x 0.70”H. 

 

System testing red-talk-back LED. 

 

Includes CB12 Connecting Block for easy system installation. 

 

SPECIFICATIONS 

 

Infrared carrier input frequency bandwidth: 30 - 60kHz. 

 

Reception range: Up to 50 feet, depending on conditions. 

 

Nominal reception angle: 55 degrees off axis. 

 

Cable requirements: See “INSTALLATION” below. 

 

Max. transmission length: 1 mile using 18 gauge wire.  

 

Maximum current output: 100mA 

 

Drives IR emitters through Xantech Connecting Blocks, Controllers, etc. 

 

Dimensions: 2.00”x3.15”x0.70” (51mm x 80mm x 18mm) 

 

Power requirements: +12VDC, 20mA. 

 
 

INSTALLATION 

 
QUICK-START  

A typical system will use an IR receiver, several emitters, and a power supply 
all connected to a connecting block. 
 

1.  Connect the IR receiver to the “IR RCVR” port on the connecting 

block. The ‘red’ connector is installed to the ‘red’ plug.  

Note:

 In some extended distances, additional 3-conductor may be required and can 

be connected to the terminals on the connecting block.  

2.  Connect the Emitters to the connecting block. The ‘yellow’ connector 

is installed to the ‘yellow’ plug. 

3.  Connect the power supply to the connecting block.  
4. Installation 

complete 

 

 

LOCAL SYSTEM APPLICATION 

In this system a 286D Dual Blink-IR Designer Emitter is shown connected to 
the “OUT” jack. A single emitter could also be used, such as the model 282D 
or 283D. If expansion beyond two emitters is required, use a Xantech 789-
44, CB60, or 791-44 Connecting Block in place of the CB12. Do not use the 
CB12 in this case. 
 

 

 