RadTarge II | Electronic Personal Dosimeter

 

by X-Z LAB

RadTarge II is a next-generation All Digital 

dosimeter covering a wide range of Gamma and 

X-Ray radiation that combines four functions 

in one:

• Radiation Dose Equivalent Rate Meter

• Accumulated Radiation Dose Meter

• Active Self-Reading Dose Meter

• Active Self-Alarming Dose Meter

RadTarge II Electronic Personal Dosimeter (EPD) 

uses a high performance YSO scintillation crystal 

combined with state-of-the-art SiPM.
RadTarge II EPD has high detection accuracy, high 

sensitivity, fast response

,

 and other significant 

advantages. By managing data systematically

,

 it can 

protect users and notify them of their environmental 

conditions instantly and accurately.
RadTarge II EPD is part of the scalable Radiation 

Monitoring Solutions by X-Z LAB, including 

RadPavise (Personal Radiation Detector, RadWall-S 

(Area Radiation Monitor), and RadSuite-Dose 

(Radiation Monitoring Software) to accommodate 

applications of any size and complexity.
RadTarge II EPD has been designed to meet 

the needs of radiation protection personnel and 

emergency responders across the United States. Its 

unique, high-contrast backlit LCD provides a clear 

indication of wearer’s equivalent dose rate and 

accumulated dose.
Multiple methods (audible, visual, and vibrating) 

are utilized to alert the wearer of alarm conditions. 

RadTarge II EPD runs for over 200 hours 

of continuous use with just one 

rechargeable 

lithium

-

ion battery.

RadTarge II EPD comes with additional capabilities 

including data logging, personnel tracking and more.
For other product features and benefits please refer 

to 

http://www.x-zlab.com/

Operating Instructions

Basic Operation

Two-key operation is easy to operate and easy to use.

Powering On/Off

Press the power key for 2 seconds until screen lights 

up. Automatically enters the main interface/dose 

equivalent rate after the machine starts. Automatic 

and instant measurement of exposure level while 

displaying the current real-time dose equivalent rate. 

Press power button for 2 seconds to power off.

Cumulative Dose Interface

Press settings button (directly under power key) and 

switch to cumulative dose, to display the cumulative 

dose equivalent.

Setup Mode

Press the settings button until settings interface is 

displayed. Press the settings button to change settings 

for sound alarm and vibration alarm. Press power 

button to turn on / off.

Threshold Settings

Enter setup mode, press the settings button 3 times, 

‘AL SET’ will flash in display. Then press power 

button to setup. Threshold level values will start 

flashing; press the settings button to choose values. 

Press power button to apply changes.

 Dose Clearing

Enter setup mode. Press settings button 4 times 

to display dose-clearing interface. When ‘CLR’ is 

displayed, press the power button to clear dose. 

When ‘YES’ is displayed, press the power key to 

confirm. When ‘DONE’ is displayed, dose is cleared. 

Press Settings Button at any time to cancel.
Press the settings button in any setting interface to 

EXIT setup mode and return to main interface. 

Data Transfer / Charging Function

Turn on RadTarge II. Connect it to PC through 

MicroUSB. It can transfer data to PC via RadSuite-

Dose 

s

oftware and manage personal dose of record.

Insert MicroUSB line, charging light indicates 

charging status.