X-SENSORS FC 10 Manual Download Page 1

Measuring system

 

Measuring range [Max]: 

1 kN 

Overload protection (of [Max]): 

150 % 

Precision (of [Max]): 

0,002 

Readout [d]: 

1 N 

Test frequency: 

1000 Hz 

Display

 

Display digit height: 

1 cm 

 

Functions

 

Data hold function: 

yes 

Display revolving: 

yes 

Function to set limits: 

yes 

Peak function: 

yes 

Visual ready signal: 

yes 

Environmental conditions

 

Maximum operating temperature: 

40 

O

C  

Minimum ambient temperature: 

-10 

O

Power supply

 

Charging time: 

4 h 

Input voltage: 

100 V - 240 V 

n/a: 

CH EURO 

Power supply

 

Operating time (Backlight off): 

20 h 

 

Service

 

DAkkS Calibration certificate  

963-262  

(Pressure): 

DAkkS Calibration certificate  

963-162  

(Tensile): 

DAkkS Calibration certificate  

963-362  

(Tensile/Pressure): 

ISO Calibration certificate (Tensile):  

961-162 

 
 

Category

 

Category: 

Force gauges 

Product Group: 

Electronic force-measuring  
device 

Packaging & shipping

 

Delivery: 

24 h 

Dimensions packaging (WxDxH): 

340 x 155 x 110 mm  

Gross weight: 

1,200 kg 

Net weight: 

940 g 

Shipping method: 

Parcel service 

UN number: 

3496 

Construction

 

Casing material: 

metal 

Dimensions of display device 

145 x 73 x 34 mm  

(WxDxH): 

X-SENSORS GmbH l Steinbrechstr. 9, 71106 

– Magstadt, Deutschland l Tel: +49 7159/49697-0 l [email protected] l www.sensorshop.com 

FC 

X-SENSORS GmbH 
Magstadt, 

Deutschland

 l Tel: +49 7159/49697-0 

[email protected] l www.sensorshop.com 

Kompetenz in Messtechnik und Kundenbetreuung 

Summary of Contents for FC 10

Page 1: ...sure DAkkSCalibrationcertificate 963 162 Tensile DAkkSCalibrationcertificate 963 362 Tensile Pressure ISOCalibrationcertificate Tensile 961 162 Category Category Forcegauges ProductGroup Electronicforce measuring device Packaging shipping Delivery 24h Dimensionspackaging WxDxH 340x155x110mm Grossweight 1 200kg Net weight 940g Shippingmethod Parcelservice UN number 3496 Construction Casingmaterial ...

Page 2: ...ing range the device will give clear acoustic and visualsignals Internalmemoryforupto1000 measurements DatainterfaceRS 232 onlyfor connection to theprinter Selectable AUTO OFF function or permanent operation Deliveredin a hard carryingcase Selectable measuringunits N kg oz lb Standard attachments asshown below Can be mounted on all teststands with adapterplate Technicaldata Precision 0 2 of Max In...

Page 3: ... the device to print out the measurements GLP ISO recordkeeping of measurements withdate time and serial number Only withprinters Measuringunits Weighing units can be switched to e g non metric at the touch of a key Please refer to website for more details Measuringwithtolerance range Upper and lowerlimiting can be programmed individually e g for sorting and dosing ZERO Resets the display to 0 Bat...

Page 4: ... GB X SENSORS GmbH l Steinbrechstr 9 71106 Magstadt Deutschland l Tel 49 7159 49697 0 l info sensorshop com l www sensorshop com FC X SENSORS GmbH Magstadt Deutschland l Tel 49 7159 49697 0 info sensorshop com l www sensorshop com Kompetenz in Messtechnik und Kundenbetreuung ...

Page 5: ...3 Backlight 11 4 Key Sound 11 5 Date time 11 6 Calibration 12 7 Default 12 5 Language 12 6 Info 12 4 Communication Port 12 1 USB Recharge 12 2 Multifunction port 13 4 2 1 RS 232 13 4 2 2 Setpoint Output 13 5 Maintenance and Calibration 14 1 Maintenance 14 2 Charging 14 3 Calibration 14 4 Troubleshooting 15 6 Declaration of Conformity 18 X SENSORS GmbH l Steinbrechstr 9 71106 Magstadt Deutschland l...

Page 6: ...urself it may damage the instrument 6 Please use and store it in a suitable environment as not to reduce the service life or cause failure 7 To avoid injury do not point the light beam of the instrument or let it reflect into the eyes of people or animals 8 Do not leave the device close to water or any other liquid to avoid damage 9 If the instrument isn t used for an extended period of time batte...

Page 7: ... upper limit and lower limit that is OK The measured value between the lower limit and 75 of the lower limit which means it is below the lower limit Fig 1 1 1 2 LCD Screen Fig 1 2 X SENSORS GmbH l Steinbrechstr 9 71106 Magstadt Deutschland l Tel 49 7159 49697 0 l info sensorshop com l www sensorshop com FC X SENSORS GmbH Magstadt Deutschland l Tel 49 7159 49697 0 info sensorshop com l www sensorsh...

Page 8: ... Select the appropriate model you need before use Accuracy 0 3 F S Units N kgf ozf and lbf Selectable Display 160 128 matrix LCD with Backlight Overload Capacity 150 of max LCD flashes beyond 110 of max Measurement mode Track Peak and Preset Data Sampling Rate 1000 Hz Memory 500 data Set Point Programmable high and low limits Power 3 6VDC 450mAH Ni MH rechargea ble batteries Charger Adaptor USB BM...

Page 9: ...nt press to enter and then select Unit to enter Choose the unit you desired here can change the Test Modes one to an Under the measure interface just press other You can also set it in Menu see 3 2 and Track The real time measuring mode Under this mode press the zero key you can remove the tare force Peak In Peak mode the maximum of force will be measured and displayed Under this mode press and th...

Page 10: ...em later During the measurement press the key to store a value and the storage Icon will be displayed The data stored is the one displayed currently So in Track and Preset mode it is the current force value measured in Peak mode it is the peak value 4 Browse and print data All data stored in the memory can be browsed or printed by the mini printer See chapter 3 3 1 and 3 3 2 for details 3 Setup 3 ...

Page 11: ...Fig 3 3 You can browse or print wireless mini printer and delete some in browse or all data in memory 3 3 1 Browse Enter Browse the data in memory can be reviewed in the order saved Press or to move and select Maximum number of data is the one obtained recently Press and a small window will pop off Here you can select Delete or Print See Fig 3 4 Fig 3 1 Fig 3 3 Fig 3 2 X SENSORS GmbH l Steinbrechs...

Page 12: ...If Selected is chosen enter the range of number will be needed If All is selected a confirm window will appear to ask you confirm See Fig 3 6 Fig 3 6 X SENSORS GmbH l Steinbrechstr 9 71106 Magstadt Deutschland l Tel 49 7159 49697 0 l info sensorshop com l www sensorshop com FC X SENSORS GmbH Magstadt Deutschland l Tel 49 7159 49697 0 info sensorshop com l www sensorshop com Kompetenz in Messtechni...

Page 13: ... and so on can be set Fig 3 8 3 4 1 Display There are two display modes Obverse Reverse show as Figure 3 7 According to actual needs select the appropriate display mode shown in Fig 3 9 Fig 3 7 Fig 3 9 Obverse Reverse Fig 3 8 X SENSORS GmbH l Steinbrechstr 9 71106 Magstadt Deutschland l Tel 49 7159 49697 0 l info sensorshop com l www sensorshop com FC X SENSORS GmbH Magstadt Deutschland l Tel 49 7...

Page 14: ...ry will be reduced Fig 3 11 3 4 4 Key Sound Key sound can be turned on or off by this setting shown in Fig 3 12 Fig 3 12 3 4 5 Date time System date and time can be adjusted under this menu Press to adjust the number and press to move the next digit Shown in Fig 3 13 X SENSORS GmbH l Steinbrechstr 9 71106 Magstadt Deutschland l Tel 49 7159 49697 0 l info sensorshop com l www sensorshop com FC X SE...

Page 15: ...del ver sion and serial number See Fig 3 15 Fig 3 15 4 Communication Port The force gauge has two kinds of ports for recharging and communicating with PC and other equipment 4 1 USB Recharge Using this port you can connect the gauge to the computer for transform data to PC in accordance with USB2 0 12 FC BA e 1410 X SENSORS GmbH l Steinbrechstr 9 71106 Magstadt Deutschland l Tel 49 7159 49697 0 l ...

Page 16: ...int outputs are NPN open collector The internal circuit of setpoint output is shown Fig 4 1 4 2 Multifunction port The assignment of pins is shown in Table 4 1 Table 4 1 Pin Assignment Pin Description 1 RS232 Tx 2 Rx 3 Gnd 4 Setpoint Output B 5 6 Setpoint OutputC Common 7 Setpoint Output A 8 X SENSORS GmbH l Steinbrechstr 9 71106 Magstadt Deutschland l Tel 49 7159 49697 0 l info sensorshop com l w...

Page 17: ...ies life 2 Charging When the batteries are low the icon will be displayed The batteries should be charged immediately Connect the gauge and the charger using the USB cable and then connect the charger with AC socket to start charging It takes about 3 4 hours for completely charging 3 Calibration Because of the sensor s material performance or the influence of external factors there may be errors i...

Page 18: ...and Exit NO Fig 5 3a Press or to select then press If YES is selected Calibrate complete is displayed see 5 3 b 5 4 Troubleshooting If the force gauge in use processes such as errors please accord to the following way for troubleshooting see table 5 3 Do not disassemble the gauge by yourself to repair If you cannot resolve the fault yourself please contact our company 5 3 a 5 3 b Calibration times...

Page 19: ...Error is too large The gauge is not calibrated Calibration force gauge The tare has not been removed Zeroing Appendix A 1 Packing List A 2 Dimensions A 3 Measuring adapters X SENSORS GmbH l Steinbrechstr 9 71106 Magstadt Deutschland l Tel 49 7159 49697 0 l info sensorshop com l www sensorshop com FC X SENSORS GmbH Magstadt Deutschland l Tel 49 7159 49697 0 info sensorshop com l www sensorshop com ...

Page 20: ... 1 10 0 01 22 00 0 02 352 5 0 5 FC 500 Capacity Resolution 500 0 5 50 0 05 110 0 0 1 1762 2 FC 1K Capacity Resolution 1000 1 100 0 1 220 0 0 2 3525 5 X SENSORS GmbH l Steinbrechstr 9 71106 Magstadt Deutschland l Tel 49 7159 49697 0 l info sensorshop com l www sensorshop com FC X SENSORS GmbH Magstadt Deutschland l Tel 49 7159 49697 0 info sensorshop com l www sensorshop com Kompetenz in Messtechni...

Reviews: