Wiring and Connections

WyreStorm recommends that all wiring for the installation is run and terminated prior to making connections to the switcher.  Read through this section in it’s 
entirety before running or terminating the wires to ensure proper operation and to avoid damaging equipment.

 

 IMPORTANT! Wiring Guidelines

 

•  The use of patch panels, wall plates, cable extenders, kinks in cables, and 

electrical or environmental interference will have an adverse effect on 
signal transmission which may limit performance.  Steps should be taken 
to minimize or remove these factors completely during installation for best 
results.

•  WyreStorm recommends the use of shielded category cable to minimize 

signal noise and interference.

•  WyreStorm recommends using pre-terminated HDMI cables due to the 

complexity of these connector types. Using pre-terminated cables will 
ensure that these connections are accurate and will not interfere with the 
performance of the product.

.

IR TX/RX Guidelines

 

•  Using WyreStorm infrared emitters and receivers is the best way to ensure 

that most IR coding formats are transmitted and received by the NetworkHD 
system. Other 3rd party emitters and receivers can be used; however, these 
devices must operate in the same manner as the WyreStorm devices.

•  Due to differences in IR across 3rd party control systems their IR ports 

should never be connected directly to a NetworkHD system as an 
incompatibility may exist. WyreStorm offers a cable that compensates for 
voltage differences as well adjusts for differences in the pins used within the 
port. Refer to the 

CAB-IR-LINK

 product page for more information.

IR TX Port Pinout

Connection for IR TX (transmit) uses a 3.5mm (1/8in) mono plug.

Tip:

Anode

Sleeve: Cathode (IR Signal)

IR RX/IR EXT Port Pinout

Connection for IR RX (receive) uses a 3.5mm (1/8in) stereo jack that outputs 
+5V DC to power the included IR receiver. 

Tip:
Ring:

IR Signal

+5V DC

Sleeve: Ground (GND)

RS-232 Wiring

Most control systems and computers are DTE where pin 2 is RX, this can vary 
from device to device. Refer to the documentation for the connected device for 
pin functionally to ensure that the correct connections can be made.

3rd Party Device

Pin 2 TX (Transmit) ---> To ---> RX (Receive)
Pin 3 RX (Receive)

---> To ---> TX (Transmit)

Pin 5 G (Ground)

---> To ---> G (Ground)

WyreStorm Connector

Note: Pins not shown in table have no connection.

IR Code Settings

This matrix has 2 different IR code sets to help alleviate interference with devices that may contain a similar IR code. These various code sets can be set within 
the units web UI should the need arise to change them. We recommend that the IR code set be left to default unless absolutely required to resolve a code 
sharing issue.
1. Access the Web UI. Refer t

Accessing the Web UI

.

2. Navigate to the Settings tab within the Admin section of the Web UI. Default password is admin.
3. Under IR Code select one of the available IR code sets. Mode 1 (0x00) is the default setting.