![Wyrestorm EX-35-4K Quick Start Manual Download Page 3](http://html1.mh-extra.com/html/wyrestorm/ex-35-4k/ex-35-4k_quick-start-manual_1001867003.webp)
HDBaseT Wiring
IMPORTANT!
Wiring Guidelines
• The use of patch panels, wall plates, cable extenders, kinks in cables,
and electrical or environmental interference can have an adverse
effect on HDBaseT transmission limiting performance. Steps should
be taken to minimize these factors (or remove completely) during
installation for best results.
• While similar in nature, the HDBaseT protocol is different than Ethernet
and voltages provided for PoH can be higher than those provided by
PoE. For this reason, never connect an HDBaseT link to an Ethernet
router or switch to avoid damaging the connected devices.
Wiring for HDBaseT follows the EIA T568B standard.
Pin 1 Pin 8
Wire colors shown follow EIA/TIA-568B standard.
Pin 1:
Pin 2:
Pin 3:
Pin 4:
Pin 5:
Pin 6:
Pin 7:
Pin 8:
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
Supported Video Resolutions
The type of category cable used and the distance between the
transmitter and receiver can restrict the available video resolution.
Cable Type
Range
Supported Resolution
Cat5/5e/6
60m/197ft
1080p@60Hz 36bit
35m/115ft
1080p@60Hz 3D
4K@60Hz 4:2:0
Cat6a
70m/230ft
1080p@60Hz 36bit
40m/131ft
1080p@60Hz 36bit
1080p@60Hz 3D
35m/115ft
4K@60Hz 4:2:0
IR Wiring
IR TX (Emitter) Wiring
Connection for IR TX (transmit) uses a 3.5mm (1/8in) mono plug.
Tip:
IR Signal
Sleeve: Ground (GND)
IR RX (Receiver) Wiring
Connection for IR RX (receive) uses a 3.5mm (1/8in) stereo jack that
o5V DC to power the included IR receiver.
IMPORTANT! IR TX Connection Guidlines
• 3rd party IR receivers may require a different voltage, refer to the
documentation provided with the IR receiver before making any
connections to avoid damaging the device.
Tip:
Ring:
IR Signal
+5V DC
Sleeve: Ground (GND)
• When connecting to an IR control system use the
stereo to mono cable to remove the 5V DC.
to WyreStorm
Matrix/Transmitter/Receiver
RX/Ext input
to Control System or
Connecting Block input
Voltage on Tip from RX may be different for non WyreStorm devices.
Refer to the provided documention for voltage on this connection.
IR Signal
Ground (GND)
+5V DC (lifted in cable)
Tip:
Ring:
IR Signal
+5V DC
Sleeve: Ground (GND)
Tip:
IR Signal
Sleeve: Ground (GND)
RS-232 Wiring
RS-232 Connection Guidelines
The following wiring diagram shows the pinouts for the extender set.
While not shown, connect the TX (transmit) to RX (receive) pins at the
control system or PC side of the cable.
Most control systems and computers are DTE where pin 2 is RX, this can
vary from device to device. Refer to the documentation for the connected
device for pin functionally to ensure that the correct connections can be
made.
Wire colors shown follow EIA-561 standard.
Pin 1:
Pin 2:
TX (Transmit)
RX (Receive)
Pin 3:
Ground (GND)
1 2 3
Power Supply Wiring
The EX-35-4K can supply power via PoH to the receiver or transmitter.
The included power supply must be used on the transmitter in order for
PoH to power the receiver device.
Copyright © 2015 WyreStorm Technologies |
EX-35-4K Quickstart Guide | 160127
North America: 518-289-1294 | EMEA/ROW: 44 (0) 1793 230 343