Wybron CYGNUS MF200 User Manual Download Page 1

LED Luminaires

VN100
VN200
MF200

 

Summary of Contents for CYGNUS MF200

Page 1: ...LED Luminaires VN100 VN200 MF200 ...

Page 2: ...peed Mode 18 Stand Alone Mode 18 Fixture Physical Setup 19 User Interface 20 Controls and Indicators 20 Display Messages 21 Menu Tree 23 DMX Channel Assignments 24 RDM Functionality 26 Flash Reprogramming 26 Table 1 Strobe Effect Channel Color Jump Sequences 27 Cygnus Specifications 28 Appendix A Photometrics 31 Appendix B Color Temperature Table 34 Warranty Information 37 ...

Page 3: ...3 Document Version V1 6 This document applies to Cygnus software V1 26 and higher ...

Page 4: ...t is in conformity with the following standards Referenced Safety Standards Referenced EMC Standards EN60598 1 EN55022 EN60598 2 17 EN61000 6 3 following the provisions of the EU LV Directive 73 23 EEC and the EU EMC Directive 89 336 EEC I declare that the equipment specified above conforms to the above Directive s and Standard s Signature January 7 2010 John Sondericker III Vice President Researc...

Page 5: ...in this manual and on the fixture If you have questions about how to operate the fixture safely please contact your Wybron dealer or call Wybron directly at 1 800 624 0146 or go to www wybron com To protect yourself and others from electric shock WARNING THIS EQUIPMENT MUST BE EARTHED Protection against electric shock is assured only if the mains connected cord set is connected to a properly earth...

Page 6: ... that the structure can hold at least 10 times the weight of all installed devices Verify that all external accessories and rigging hardware are securely fastened and use an approved means of secondary attachment such as a safety cable Block access below the work area whenever installing or removing the fixture ...

Page 7: ... avez des questions sur comment faire fonctionner le dispositif en toute sécurité s il vous plaît contacter votre revendeur ou appelez WYBRON WYBRON directement au 1 800 624 0146 ou visitez le www wybron com Pour vous protéger vous et d autres contre les chocs électriques AVERTISSEMENT CET APPAREIL DOIT ETRE MIS A LA TERRE Protection contre les chocs électriques est assurée uniquement si le réseau...

Page 8: ...ure peut contenir au moins 10 fois le poids de tous les périphériques installés Vérifiez que tous les accessoires externes et matériel de calage sont solidement attachées et utiliser un approuvé des moyens de fixation secondaire tel qu un câble de sécurité Interdisez l accès sous la zone de travail pendant l installation ou le retrait du dispositif ...

Page 9: ...y observar todas las advertencias en este manual y en el aparato Si usted tiene preguntas acerca de cómo operar el equipo con seguridad por favor contacte con su distribuidor o llame al Wybron Wybron directamente en 1 800 624 0146 o vaya a www wybron com Para protegerse a sí mismo ya los demás de una descarga eléctrica ADVERTENCIA ESTE EQUIPO DEBE SER CONECTADO A TIERRA Protección contra choques e...

Page 10: ...parato sobre el nivel del suelo verificar que la estructura pueda soportar al menos 10 veces el peso de todos los dispositivos instalados Compruebe que todos los accesorios externos y hardware de montaje estén bien fijadas y utilizar un aprobado medios de fijación secundaria como un cable de seguridad Bloquear el acceso al área de trabajo cuando se esté instalando o quitando el aparato ...

Page 11: ...vor dem Einschalten oder die Installation der Leuchte Befolgen Sie die Vorsichtsmaßnahmen und beachten Sie alle Warnungen in diesem Handbuch und auf den Verkauf Wenn Sie Fragen haben wie die Leuchte sicher zu betreiben kontaktieren Sie bitte Ihren Händler oder rufen Sie Wybron Wybron direkt an 719 548 9774 oder besuchen Sie www wybron com So schützen Sie sich und andere durch elektrischen Schlag W...

Page 12: ...ere vor Verletzungen durch Stürze Wenn Aussetzung der Leuchte über dem Boden zu überprüfen dass die Struktur können mindestens 10 mal das Gewicht aller installierten Geräte halten Überprüfen Sie dass alle externen Zubehör und Montagematerial sind sicher befestigt und verwenden Sie ein zugelassenen Mittel der zweiten Befestigung zB mit einem Sicherheitskabel Block Zugang unterhalb der Arbeitsfläche...

Page 13: ...tta alla varningar i denna manual och på armaturen Om du har frågor om hur du använder fixtur säkert kontakta din Wybron återförsäljare eller ring Wybron direkt på 1 800 624 0146 eller gå till www wybron com För att skydda dig själv och andra från elektriska stötar VARNING Denna utrustning måste JORDAS Skydd mot elolyckor endast kan uppnås om elnätet anslutna sladden är ansluten till en korrekt jo...

Page 14: ...maturen över marken kontrollera att strukturen kan hålla minst 10 gånger vikten av alla installerade enheter Kontrollera att alla externa tillbehör och monteringsdetaljer sitter ordentligt fast och använda en Blockera åtkomst under arbetsområdet när du installerar eller tar bort armaturen ...

Page 15: ...ered with some other fixtures Cygnus also incorporates in lens color mixing eliminating the pixilated look of most fixtures The Cygnus uses between 7 and 12 channels of DMX depending on which resolution and mode are selected Precision control allows for smooth subtle fades or instantaneous jumps to new colors as well as strobe effects with control of speed duration and color Cygnus also has an opt...

Page 16: ...ave setting 4 Set Master Fader Option to ON a Press Menu until display reads Fdr b Press Enter c Press the or keys to select On d Press Enter to save setting 5 Set Video Mode to Off a Press Menu until display reads HSP b Press Enter c Press the or keys to select OFF d Press Enter to save setting 6 Control Cygnus with DMX a DMX channel 1 controls Red 0 100 b DMX channel 2 controls Green 0 100 c DMX...

Page 17: ...at rates between 0 25 and 30hz The Strobe Frequency channel is used to enable strobing and to select the strobe frequency If this channel is set to 0 7 strobe mode will be off and the unit will operate normally If this channel is set to 8 100 then strobe mode will be on and the strobe speed will vary from low to high The unit will strobe with a color and intensity selected from either the RGBW or ...

Page 18: ...aster and slave units also must all be set to the same DMX address Stand Alone mode will automatically run when the unit is powered up if it was running the last time the unit was powered down When running a cue the display will not time out and go blank Loop 1 demonstrates some of the abilities of the Cygnus including strobe mode Loop2 performs 60 second fades across a rainbow of 6 saturated colo...

Page 19: ...the pan screw setting the position and tightening the pan screw to hold the position Attaching Accessories to the Front Holder Cygnus VN200 and MF200 can accept up to two standard 7 5 accessories The VN100 can accept one 5 75 accessory Accessories are safely held in place with a standard spring loaded latch From the rear of the fixture pull the accessory ring toward you Load the accessory into the...

Page 20: ... change a selection for a single option in a menu The Enter button allows the user to enter down into a submenu to change a parameter or to accept the parameter currently displayed and return up one menu level Changes are saved in non volatile memory when the Enter button is pressed except when programming a user stand alone loop Stand alone loop parameters are saved when the Program Stand Alone m...

Page 21: ...ssing Enter here will allow the current resolution to be changed Fdr Third menu item Pressing Enter here will allow the Fader Mode to be changed HSP Fourth menu item Pressing Enter here will allow the Video High Speed Mode to be changed rSA Fifth menu item Pressing Enter here will allow a Run Stand Alone loop to be run PSA Sixth menu item Pressing Enter here will allow the user to Program Stand Al...

Page 22: ... Err Here are three possible causes for this error o Fan failure o Obstruction of the cooling holes in the unit o The unit is being operated in an ambient temp above the rated 40C SEr Err The RDM unique ID has been corrupted The unit will operate normally but should not be used in an RDM environment Contact the factory for assistance ...

Page 23: ...0 001 Adr rES Fdr HSP rSA PSA Menu Menu Menu Menu Menu Menu Menu Enter Enter Menu Enter Enter Menu Enter Enter Menu Enter Enter Menu Enter Enter Menu Cu1 Cu2 Cu3 Cu8 Enter Menu Menu Menu Menu Enter Enter Menu Enter Enter Menu Enter Enter Menu Menu Menu auto return Spinning circle ...

Page 24: ...controls Blue 0 100 DMX channel 4 controls White 0 100 DMX channel 5 controls Strobe Frequency 8 100 DMX channel 6 controls Strobe Duration duty cycle 8 100 DMX channel 7 controls Strobe Effect color jumping 8 100 Control Cygnus using DMX in Master Mode 16 bit Leave Cygnus addressed at channel 1 factory default DMX channel 1 controls Red Coarse 0 100 DMX channel 2 controls Red Fine 0 100 DMX chann...

Page 25: ...3 controls Green Coarse 0 100 DMX channel 4 controls Green Fine 0 100 DMX channel 5 controls Blue Coarse 0 100 DMX channel 6 controls Blue Fine 0 100 DMX channel 7 controls White Coarse 0 100 DMX channel 8 controls White Fine 0 100 DMX channel 9 controls Strobe Frequency 8 100 DMX channel 10 controls Strobe Duration duty cycle 8 100 DMX channel 11 controls Strobe Effect color jumping 8 100 ...

Page 26: ... application like Star curtain 2 or Shark display upper right Software version information DMX personality The Cygnus personalities include selection of DMX control 8 and 16 bit Master Fader on off and Video high Speed Mode on off DMX Start Address This can be set remotely through an RDM system Slot description human readable explanation of the function of each of the Cygnus s DMX channels Sensor ...

Page 27: ... Value 0 255 Sequence 0 19 No strobe effect mode 20 50 red yellow green cyan blue magenta 51 75 red red red blue blue blue 76 100 cyan blue 101 125 yellow red 126 150 green purple 151 175 red blue 176 200 yellow green 201 225 yellow blue 226 255 magenta green ...

Page 28: ...fety cable mount on fixture Precision milled aluminum construction Standard 7 5 inch lens and accessory holder on 200W units Load controlled low noise fan Legendary Wybron Reliability Made in the USA Average Lumens per Watt 23 Environmental Specifications Maximum Ambient Temperature 40 C 104 F Maximum Exterior Surface Temperature 70 C 158 F Minimum Air Space Sides 10 cm 4 Minimum Air Space Top 10 ...

Page 29: ...N100 Model number 7500 Dimensions Height 12 25 in 311 15 mm Width 6 4 in 162 6 mm Length 10 6 in 269 2 mm Weight 9 16 lbs 4 15 kg Electrical Specifications Power 1A 110 120V 50 60Hz or 1 2A 220 240V 50 60Hz ...

Page 30: ...umbers 6501 6500 Dimensions Height 8 3 in 212 mm Width 9 7 in 245 mm Length 13 8 in 349 mm Weight 14 5 lbs 6 6 kg Electrical Specifications Power 2A 110 120V 50 60Hz or 1A 220 240V 50 60Hz LQ PP LQ PP LQ PP LQ PP LQ PP LQ PP ...

Page 31: ...31 Appendix A Photometrics VN100 ...

Page 32: ...32 VN200 ...

Page 33: ...33 MF200 ...

Page 34: ...6 3500 7 3500 8 2000 9 2060 10 2120 11 2179 12 2239 13 2299 14 2359 15 2418 16 2478 17 2538 18 2598 19 2658 20 2717 21 2777 22 2837 23 2897 24 2957 25 3016 26 3076 27 3136 28 3196 29 3255 30 3315 31 3375 32 3435 33 3495 34 3554 35 3614 36 3674 37 3734 38 3793 39 3853 40 3913 41 3973 42 4033 43 4092 ...

Page 35: ...10 56 4870 57 4929 58 4989 59 5049 60 5109 61 5168 62 5228 63 5288 64 5348 65 5408 66 5467 67 5527 68 5587 69 5647 70 5707 71 5766 72 5826 73 5886 74 5946 75 6005 76 6065 77 6125 78 6185 79 6245 80 6304 81 6364 82 6424 83 6484 84 6543 85 6603 86 6663 87 6723 88 6783 89 6842 90 6902 91 6962 92 7022 ...

Page 36: ...36 93 7082 94 7141 95 7201 96 7261 97 7321 98 7380 99 7440 100 7500 ...

Page 37: ...or written authorization WYBRON INC shall not be responsible for any incidental general or consequential damages to property damages for loss of use time profits or income or any other charges The owner s obligations during the warranty period under this warranty are to notify WYBRON INC at WYBRON INC s address within one week of any suspected defect and return the goods prepaid to WYBRON INC at t...

Reviews: