Coin and credit programming
OMT VINYL – edition: 13.08.2007
10
6
Verification of power voltage
The voltage settings are marked on
the cover plate of the mains
transformer. Machines for USA are
set to 117v. They have a special
transformer according to UL standard
which is not adjustable. Jukeboxes
“UNI-Pack” are shipped with 230v
setting. Mains voltage is indicated on
the label of the transformer cover. The
mains fuse (T3.15A/230v F6A/117v)
is located on the left bottom side in-
between the three terminals for the bill
acceptor, the external mains switch
and the fluorescent lamps.
Loosen the four screws to remove the
cover plate (small arrows) to get
access to the mains transformer.
ATTENTION! Always remove power plug before opening transformer cover plate. Never
attempt any intervention to these parts unless qualified!
The position of the two plug connectors on the transformer terminals 1 to 9 (primary side) indicates
the current voltage setting. The following combinations are possible:
240v = 1 - 9
230v = 1 - 8
220v = 2 - 9
210v = 2 - 8
117v = 1 - 6
100v = 2 - 6
Notice that these settings cannot be
made on machines produced
according to UL standard (US
version).
NOTE:
Never connect the fluorescent
supply to other contact.
If you intend to change the power
voltage to a higher voltage (e.g. from
117v to 230v) it is recommended to
use a subtransformer for the
fluorescent lamps or change the
ballast according to the used voltage
(e.g. for 230v).
Netzsicherung
Mains Fuse
210-240V - T 4A
100-117V - F 6A
Leuchtstofflampen
Fluorescent Lamps
230V / 117V
V
erstärker
Amplifier
Externer Hauptschalter
External Mains switch
Schein-
annehmer
Bill-
acceptor
Achtung
Vor A nahme
er
appe
en
Netzstecker
ziehen
arning
Shock hazar
o
not open
ur
Beachtung
Nur Sicherungen
mit
gleicher
r e
un
gleichem
ert
erwen en,
um Schä en
zu ermei en
aution
To re uce
the risk of fire
replace onl
with same t p
an
rating fuses
Netzspannung
50/60 Hz
Mains Voltage
50/60 cps
240
230
220
210
117
100
Netzsicherung/
Mains Fuse
210-240V - T3,15A
100-117V - F6A
1 - 8 = 230V
Mains
voltage-Netzspannung
240V = 1 - 9
230V = 1 - 8
220V = 2 - 9
210V = 2 - 8
117V = 1 - 6
100V = 2 - 6
Temperaturwächter
thermalfuse
= 2 - 4
Deutsche Wurlitzer GmbH
Art.-Nr. 0058498 K99 210VA
VDE 0551/ EN 60742 50/60Hz
1
23456789
10
11
12
13
14
15
16
17
18
gy
br
y/r
wt
wt/r
bk
bl
bk
amplifier
mains
fluorescent
lamps
Summary of Contents for One More Time Vinyl
Page 1: ...R Operating Instructions ONE MORE TIME VINYL 21 GB ...
Page 2: ......
Page 32: ...OMT VINYL edition 13 08 2007 30 21 Wiring diagram K99 power supply ...
Page 33: ...OMT VINYL edition 13 08 2007 31 22 Wiring diagram K99 power amp ...
Page 35: ...OMT VINYL edition 13 08 2007 33 24 Wiring diagram K99 sound controler ...
Page 36: ...OMT VINYL edition 13 08 2007 34 25 Wiring diagram K99 port A ...
Page 37: ...OMT VINYL edition 13 08 2007 35 26 Wiring diagram K99 mute ...
Page 38: ...OMT VINYL edition 13 08 2007 36 27 Wiring diagram K99 power supply Euro 230V ...
Page 39: ...OMT VINYL edition 13 08 2007 37 Wiring diagram K99 power supply UL USA 117V ...
Page 41: ......