ba75541e07 03/2018

IQ S

ENSOR

N

ET

 

MIQ/R6

IQ S

ENSOR

N

ET

 SIX CHANNEL RELAY OUTPUT MODULE

Po

we

r

!

OK

Summary of Contents for IQ SENSOR NET MIQ/R6

Page 1: ...OPERATING MANUAL ba75541e07 03 2018 IQ SENSOR NET MIQ R6 IQ SENSOR NET SIX CHANNEL RELAY OUTPUT MODULE Power OK...

Page 2: ...MIQ R6 2 ba75541d07 03 2018 Copyright 2018 Xylem Analytics Germany GmbH Printed in Germany...

Page 3: ...n 8 2 2 1 Authorized use 8 2 2 2 Requirements for safe operation 8 2 2 3 Unauthorized use 8 2 3 User qualification 8 3 Installation 9 3 1 Scope of delivery 9 3 2 Basic principles of installation 9 3 2...

Page 4: ...List of contents MIQ R6 4 ba75541e07 03 2018 7 Indexes 22 7 1 Explanation of the messages 22 7 1 1 Error messages 22 7 1 2 Info messages 22...

Page 5: ...al has a modular structure like the IQ SENSOR NET itself It consists of a system operating manual and the operat ing manuals of all the components used Please file these component operating manuals in...

Page 6: ...puts can be used for general monitoring functions With the standard MIQ module housing the MIQ R6 has the same character istics as all MIQ modules regarding stability leakproofness and weather resis t...

Page 7: ...s might be damaged if the actions mentioned are not taken 2 1 2 Safety signs on the product Note all labels information signs and safety symbols on the product A warning symbol triangle without text r...

Page 8: ...tly described in this operating manual example connecting electrical lines to the terminal strip 2 2 3 Unauthorized use The product must not be put into operation if it is visibly damaged e g after be...

Page 9: ...t location The measurement location must meet the environmental conditions specified in section 6 1 GENERAL DATA Controlled environmental conditions Work on the open instrument e g during mounting ins...

Page 10: ...upply of permanently mounted equipment with separate mains connection in compliance with the following regulations IEC 60947 1 IEC 60947 3 in the vicinity of the equipment recommendation Flame resista...

Page 11: ...cables Large clamping range 7 to 13 mm This cable gland is required for cable sheaths with an outside diameter of more than 10 mm and is screwed into the enclosure via an extension piece General inst...

Page 12: ...cable gland Screw a small cable gland with sealing ring into each remaining free opening and close it with a blind plug WARNING No free wires are allowed to project into the housing Oth erwise there...

Page 13: ...anger of physical contact must only be connected when they are voltage free The terminal strip of the MIQ R6 output module has two segments for relay outputs with three relay connec tions each R1 R3 a...

Page 14: ...ed under the terminal strip 6 Tighten the coupling ring pos 3 in Fig 3 1 WARNING No free wires are allowed to project into the housing Oth erwise there is a danger that areas safe to contact could com...

Page 15: ...MIQ R6 Installation 15 ba75541d07 03 2018 7 Close the module...

Page 16: ...s adjust outputs check the condition of the outputs Functions of relay outputs Relay output System monitoring Sensor monitoring Limit indicator Frequency controller Pulse width output Cleaning Sensor...

Page 17: ...5 1 Maintenance The MIQ R6 requires no special maintenance The general maintenance of IQ SENSOR NET components is described in the IQ SENSOR NET system operating manual 5 2 Cleaning The cleaning of IQ...

Page 18: ...ns Fig 6 1 Dimension drawing of MIQ module dimensions in mm Mechanical structure 100 148 144 0 115 0 70 0 144 0 45 0 72 0 52 2 11 0 16 5 Side view Front view Rear view Stack mounting Maximum number of...

Page 19: ...C 65 C 13 149 F Relative humidity Mounting installation maintenance 80 Yearly average 90 Dew formation Possible Site altitude Max 2000 m above sea level Applicable norms EN 61010 1 UL 61010 1 CAN CSA...

Page 20: ...RNET ter minator terminating resistor Number of relay con tacts 6 Terminal type Screw type terminal strip accessible by opening the lid Terminal ranges Solid wires 0 2 4 0 mm2 AWG 24 12 Flexible wires...

Page 21: ...Q R6 Technical data 21 ba75541d07 03 2018 Relay functions System monitoring Sensor monitoring Limit indicator Frequency output Pulse width output Cleaning Sensor controlled Manual control Alarm contac...

Page 22: ...ny info messages Information about Contents and structure of the log book and Structure of the message code can be found in the LOG BOOK chapter of the IQ SENSOR NET system operating manual All messag...

Page 23: ......

Page 24: ...buildings factories and farms In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications...