background image

MIQ/PS

Maintenance and cleaning

4 - 1

ba64113e02

12/2005

4

Maintenance and cleaning

4.1

Maintenance

The MIQ/PS requires no special maintenance. The general mainte-
nance of IQ S

ENSOR

 N

ET

 components is described in the IQ S

ENSOR

 

N

ET

 system operating manual.

4.2

Cleaning

The cleaning of IQ S

ENSOR

 N

ET

 components is described in the IQ 

S

ENSOR

 N

ET

 system operating manual.

Luggage Point WRP Water Reclamation (MIQ/PS) Vendor Manual

Doc Id: 006465

Active: 02/04/08

Page 15 of 20

Summary of Contents for IQ SENSOR NET MIQ/PS

Page 1: ...12 2005 MIQ PS Operating Manual Power OK IQ SENSOR NET wide range power supply module Mains voltage 100 240 VAC Luggage Point WRP Water Reclamation MIQ PS Vendor Manual Doc Id 006465 Active 02 04 08 P...

Page 2: ...so we cannot guarantee that there are absolutely no errors in this manual Therefore we are sure you will understand that we cannot accept any legal claims resulting from the data figures or descriptio...

Page 3: ...uctions 2 1 2 1 Authorized use 2 2 2 2 General safety instructions 2 2 3 Installation 3 1 3 1 Scope of delivery 3 1 3 2 Installation in the IQ SENSOR NET 3 1 3 3 Connecting the power supply 3 1 4 Main...

Page 4: ...List of contents MIQ PS 0 2 ba64113e02 12 2005 Luggage Point WRP Water Reclamation MIQ PS Vendor Manual Doc Id 006465 Active 02 04 08 Page 4 of 20...

Page 5: ...ystem itself It consists of a system operating manual and the operating manuals of all the components used Please file these component operating manuals into the ring binder of the system operating ma...

Page 6: ...MIQ modules regarding stability leakproofness and weather resistance It also provides the same wide variety of instal lation options stacked mounting canopy mounting tophat rail mounting etc The numbe...

Page 7: ...ial user qualifications The MIQ PS may only be connected to the power supply by a trained electrician General safety instructions Safety instructions in this operating manual are identified by the war...

Page 8: ...erational safety The failure free function and operational safety of the MIQ PS is only guaranteed if the generally applicable safety measures and the special safety instructions in this operating man...

Page 9: ...ily switched on and off from a single location 3 3 Connecting the power supply Warning If the power supply is connected incorrectly it may represent a danger to life from electric shock Pay attention...

Page 10: ...ee wires must be allowed to project into the housing Otherwise there is a danger that safe areas could come into contact with danger ous voltages This could result in a life threatening electric shock...

Page 11: ...d occur 1 Cut off the cable to the required length 2 Strip the cable insulation for approx 45 mm 3 Bare the wires of phases L and N and fit them with wire end sleeves 4 If present cut off the protecti...

Page 12: ...ases L and N to the terminal strip Make sure that the cable assignment agrees with the specification on the ter minal label under the terminal strip 10 Tighten the coupling ring pos 3 in Bild 3 2 1 3...

Page 13: ...T Always cut off any wires that are not in use as closely as possible to the cable gland Bild 3 3 Closing the cable opening 11 Close the module 12 Screw the remaining cable glands with the sealing rin...

Page 14: ...Installation MIQ PS 3 6 ba64113e02 12 2005 Luggage Point WRP Water Reclamation MIQ PS Vendor Manual Doc Id 006465 Active 02 04 08 Page 14 of 20...

Page 15: ...ntenance The general mainte nance of IQ SENSOR NET components is described in the IQ SENSOR NET system operating manual 4 2 Cleaning The cleaning of IQ SENSOR NET components is described in the IQ SEN...

Page 16: ...Maintenance and cleaning MIQ PS 4 2 ba64113e02 12 2005 Luggage Point WRP Water Reclamation MIQ PS Vendor Manual Doc Id 006465 Active 02 04 08 Page 16 of 20...

Page 17: ...ance with IEC 60038 Mains connection2 pole N and L Line cross section of mains connection Europe 1 5 4 0 mm2 USA AWG 14 12 Fuse rating on the operator side 16 A maximum Power consumption Approx 25 W O...

Page 18: ...CAN CSA C22 2 No 1010 1 IQ SENSOR NET connec tions 3 Additional connectable SENSORNET termi nator terminating resistor Terminal type Screw type terminal strip accessible by raising the lid Terminal r...

Page 19: ...Luggage Point WRP Water Reclamation MIQ PS Vendor Manual Doc Id 006465 Active 02 04 08 Page 19 of 20...

Page 20: ...arl Slevogt Stra e 1 D 82362 Weilheim Germany Tel 49 0 881 183 0 49 0 881 183 100 Fax 49 0 881 183 420 E Mail Info WTW com Internet http www WTW com Luggage Point WRP Water Reclamation MIQ PS Vendor M...