TReX User Manual v15.30 Firmware
and repeated with 5 seconds between transmissions. Any remaining messages to transmit are
cancelled if the state changes again to low before all transmissions are complete. The
messages are not retransmitted periodically.
Typical usage:
*IN_CONFIG_H=1:2,3,5,0,0<CR>
*IN_MSG_L
Specifies the low level message that will be transmitted if configured. Input messages must
always use WT Protocol.
Typical usage:
.
*IN_MSG_L=1:WT1234560A10 IN_1_LOW<CR>
*IN_MSG_H
Specifies the high level message that will be transmitted if configured. Input messages must
always use WT Protocol.
Typical usage:
*IN_MSG_H=1:WT1234560A10 IN_1_HIGH<CR>
*IN_ANALOG
Specifies the high and low ADC count thresholds for an analog input to be considered a digital
HIGH or digital LOW. When these thresholds are exceeded, then programmed messages for
HIGH and LOW levels can be transmitted. All ADC counts are the SCALED ADC counts.
*IN_ANALOG=1H,1L,2H,2L,3H,3L
<CR>
Where:
1H = Input voltage high (x10)
1L = Input voltage low (x10)
2H = ADC1 voltage high ADC count
2L = ADC1 voltage low ADC count
3H = ADC2 voltage high ADC count
3L = ADC2 voltage low ADC count
Typical usage:
*IN_ANALOG=138,114,200,100,500,400<CR>
© WTE Limited, 2022 – Christchurch New Zealand