WRT ZZM-801CS6M Instruction Download Page 1

IP System Instruction

R

WRT

Z Z M - 8 0 1 C S 6 M

TP

YE

:A

/A

,I

 

Thank you for choosing WRT. Please read this manual before using. WRT 
reserves  the  right  to  change  specifications  or  designs  described  in  this 
manual without notice and obligation.

Summary of Contents for ZZM-801CS6M

Page 1: ...truction R WRT ZZM 801CS6M TPYE A A I Thank you for choosing WRT Please read this manual before using WRT reserves the right to change specifications or designs described in this manual without notice and obligation ...

Page 2: ...1 2 2 3 4 5 14 15 16 17 18 1 0 Features Functions 2 0 Equipment Description Gate Station Description 3 0 Caution 4 0 Installation 5 0 Operation 6 0 Specification 7 0 Terminal Description 8 0 Trouble Shooting 9 0 Wiring ...

Page 3: ...ideo 3 LCD follow up operation menu 4 Digital Audio Encoding 5 Multichannel Guard Center can call other spare door phones while Gate Station are talking with door phone 7 Divert No Disturb multi monitors and multi centers choose center automatically 8 Can call talk with Guard Center which can remote unlock 9 Unlock by password or cards disarm by cards 10 Snapshot function optional 11 Burglar alarm...

Page 4: ...d 4 IC Card Induction Zone 5 Microphone 6 Speaker 7 Camera Adjustment 8 Volume Adjustment 9 Socket for power input and unlock signal output 10 Network Connector 11 Gate Station Alarm selection 12 Socket for Door contact and Lift control ENC 485A GND 485B JP2 1 2 3 外接口1 外接口2 1 7 8 9 5 10 12 11 6 2 3 4 18V UNLOCK GND Front View Back view ...

Page 5: ...d in 3m deep down the ground so as to keep from the signal interference and lightning 7 The wire ends should not be installed in the tube or place where is humid 8 Turn on the power supply after installing the whole system well 9 Keep IC card be water resistant antimagnetic antifluting 10 Keep the IC induction zone clean in order to enhance reliability to identify information 11 For the first usag...

Page 6: ...cm above the ground Figure 1 2 Make a wiring hole on the bottom case fix the fixed bracket on the bottom case Fiture2 3 Insert the wires through the wiring hole then put the bottom case into wall and embedded Cement Figure 3 4 Connect all Gate Station wires then fix Gate Station on the fixed bracket Figure 4 wall wall Figure Figure 2 1 Figure 3 Figure 4 ...

Page 7: ... of computer system 4 Every twice press the button not more than 20s or it will exit operating state When standby the screen will show The Gate Station works after all parameters are correct Press first then press and release the two keys at the same time The screen will show Input 1 8 digits managing PIN setting last time If it is first time to input it should be input the original PIN 88888888 a...

Page 8: ...vice type 2 Device NO 3 Network setting 4 Image setting 5 Delay setting 6 Image sharpness 7 Timing 8 Install location 9 Return 专业保障 恒久关爱 Professional Guarantee Forever Concerned 按功能前的数字编号选中该功能 否则返回上一界面 Choose number for function or return to previous 专业保障 恒久关爱 Professional Guarantee Forever Concerned 按功能前的数字编号选中该功能 否则返回上一界面 Choose number for function or return to previous 请选择 选中有 Please select mea...

Page 9: ... Input Unit NO and Local NO as above When input numbers there will be a interface about digit and alphabet selection except 0 button as follows Press 1 to select serial number as digit press 2 to select serial number as alphabet If serial number is long set the number step by step 1 1 2 A 请输入本区编号 当前区号为 01 01 1 Group NO 2 Building NO 3 Unit NO 4 Local NO 5 Return 1 Group NO 2 Building NO 3 Unit NO ...

Page 10: ...l IP Highlight means selected input the data according to actual distribu tion press to confirm The interface will be Subnet mask input screen after modified successfully Input Subnet mask and press to confirm Input all IP address as above or to return to previous menu or exit automatically after 20s When non input status press 8 Note If no back up center IP back up Master Station and so on no nee...

Page 11: ... of screen brightness contrast and saturation Escalate from 1 to 99 There 10 Escalate from 1 to 10 levels of camera brightness contrast and saturation Please restart the device after set Delay setting Press 5 on device setting menu the screen shows 专业保障 恒久关爱 Professional Guarantee Forever Concerned 按功能前的数字编号选中该功能 否则返回上一界面 Choose number for function or for return to previous 1 Screen brightness 2 S...

Page 12: ... Station must less than 10s for ring duration of door phones or message function will be invalid Please restart the device after set Image sharpness Press 6 on device setting menu the screen shows Press 0 1 2 to select the camera sharpness as low mid high press to confirm Then Gate Sta tion will restart automatically after 3s Timing Press 7 on device setting menu when the connection is normal the ...

Page 13: ...wiping delete card by room NO and delete card by swiping a Issue card by room NO Issue card by room NO of the tenant On the Access Control interface press 1 the screen will show 选择设备安装位置 0 室内 2 户外 0 当前状态 室内模式 专业保障 恒久关爱 Professional Guarantee Forever Concerned 按功能前的数字编号选中该功能 否则返回上一界面 Choose number for function or return to previous 1 Issue card by room NO 2 Issue card by swiping 3 Delete card by ro...

Page 14: ...ce the screen will show Swipe the card at the induction zone according to prompt it means the card issued successfully Note Tenant can use the card which is issued successfully to unlock c Delete card by room NO Delete card by room NO of the tenant 1 Issue card by room NO 2 Issue card by swiping 3 Delete card by room NO 4 Delete card by swiping 5 Return 1 Issue card by room NO 2 Issue card by swip...

Page 15: ...Swipe the card at the induction zone according to prompt it means the card issued successfully Press to exit Note The deleted card will be invalid card can not release the door until registered again ial format D 1 Issue card by room NO 2 Issue card by swiping 3 Delete card by room NO 4 Delete card by swiping 5 Return 1 Issue card by room NO 2 Issue card by swiping 3 Delete card by room NO 4 Delet...

Page 16: ...creen shows Press 0 to select Room NO as digit press 1 to select Room NO as alphabet then press to confirm it means modify successfully Enter Building NO digit input screen after modified then input the data and select category of Room 是否自动重启 0 否1 是 2自动重启间隔 3自动重启时间 4返回 按功能前的数字编号选中该功能 否则返回上一界面 是否字母房号 0 数字 1 字母 专业保障 恒久关爱 Professional Guarantee Forever Concerned 按功能前的数字编号选中该功能 否则返回上一界面 Choose number ...

Page 17: ...to set the device auto restart When enable the auto restart the icon of auto restart interval will be light up and set the days interval press to confirm Then icon of auto restart time will be light up and set the time press to confirm Please restart after set Language There are two languages for option English and Chinese Restart or not 0 NO 1 YES 2Auto restart interval 3Auto restart time 4Return...

Page 18: ...dify date 7 Modify time 8 Modify week 9 Key tone ON OFF 0 System info 专业保障 恒久关爱 Professional Guarantee Forever Concerned 按功能前的数字编号选中该功能 否则返回上一界面 Choose number for function or return to previous 1 Ring volume setting 2 Talk volume setting 3 Return 专业保障 恒久关爱 Professional Guarantee Forever Concerned 按功能前的数字编号选中该功能 否则返回上一界面 Choose number for function or return to previous 专业保障 恒久关爱 Professional Guaran...

Page 19: ...set not to enable snapshot function press 1 to enable snapshot function P If snapshot function is enabled both on Gate Station and Center when this device calls a tenant or Guard Center PC will take the photo Password setting Press 3 on others menu the screen shows Talk volume 专业保障 恒久关爱 Professional Guarantee Forever Concerned Snapshot or not 0 NO 1 YES 专业保障 恒久关爱 Professional Guarantee Forever Con...

Page 20: ...at new super password is modified successfully Note Original password is 88888888 Must use new password when enter setting menu b Modify unlock password Press 2 on password setting interface to the menu 1 Modify super password 2 Modify unlock password 3 Modify special password 4 Return Please input new super password 专业保障 恒久关爱 Professional Guarantee Forever Concerned 专业保障 恒久关爱 Professional Guarant...

Page 21: ...assword is modified successfully Note Original password is new password is 6 digit 00000000 c Modify special password Press 3 on password setting interface to the menu Input room NO 3 digit is floor NO 3 digit is room NO press to confirm the screen shows Please input new unlock password 专业保障 恒久关爱 Professional Guarantee Forever Concerned 专业保障 恒久关爱 Professional Guarantee Forever Concerned Please inp...

Page 22: ...e the same it will prompt that new special password is modified successfully Note New password is 6 digit Press can switch to next room No during operation Modify date Press 6 on others menu the screen shows Input the date and press to confirm Modify time Press 7 on others menu the screen shows 专业保障 恒久关爱 Professional Guarantee Forever Concerned 专业保障 恒久关爱 Professional Guarantee Forever Concerned Pl...

Page 23: ...k Press 8 on others menu the screen shows Input the week and press to confirm Key tone ON OFF Press 9 on others menu the screen shows Please input time Please input week 专业保障 恒久关爱 Professional Guarantee Forever Concerned 专业保障 恒久关爱 Professional Guarantee Forever Concerned ...

Page 24: ... more than the magnetic delay time and no short circuit it will report the alarm When plug jumper on pin 2 3 on the pin socket if ENC M I and GND are short circuit more than the magnetic delay time and still be connecting it will report the alarm Note After all settings are completed please restart Gate Station to refresh datas There is a JP3 pin socket he back of Gate Station when wiring distance...

Page 25: ... number does not exist the screen will prompt If the number is correct and the line is not busy it will ring out the screen will show Input room NO for call 00 for center Welcome Welcome Welcome Input room NO for call 00 for center Input room NO for call 00 for center 呼叫格式 位层号 位房号 1 1 Dial format 1 digit floor NO 1 digit room NO 呼叫格式 1位层号 1位房号 Dial format 1 digit floor NO 1 digit room NO 不存在该房号 Ro...

Page 26: ...ndby state automatically When Gate Station is calling the tenant door phone is IP system and Gate Station with message function if time out and no one answer the call Gate Station will prompt Press to leave a mess age in 5s others to hang up visitor can press to leave message for tenant the screen display the countdown Calling Tenants Divert on Welcome Welcome 呼叫格式 1位层号 1位房号 Dial format 1 digit fl...

Page 27: ...l be back to normal automatically If someone answers the call can last 120s system will cut off the line if over time Unlock the door by Guard Center while talking If divert on it will transfer the call to the Center If the Center no answer or is busy and with Back up Center it will transfer the call to the Back up Center If the Center is busy no Back up Center it will prompt busy tone please call...

Page 28: ...uld input 11000002 Unnormal unlock Force to unlock the method is to input public password any digit or alphabet or Room NO special password any digit or alphabet Room ID should be input according to dial format Just like input 0000019 or 110000027 the door open and send the alarm to Guard Center at the same time Unlock by Access Control card When standby the tenant use IC card to close to the indu...

Page 29: ...s validation Du Du tone can be heard the screen will prompt invalid card Operation Operation Welcome Input room NO for call 00 for center 呼叫格式 1位层号 1位房号 Dial format 1 digit floor NO 1 digit room NO 已开锁 请进 Unlock come in ...

Page 30: ...distance IC card access time IC card access distance Capacity of cards Protection grade Dimensions Size of Bottom case 18VDC 370mA Refer to setting time 45 95 5 570mA IP33 177 390 45mm Not include bottom case 152 350 63mm 0 0 30 C 55 C 30mV Ic 20mm 2 1 CAT5 1 RVV3X1 0mm power wire RJ45 TCP IP Use a network switch or router in 60m add a fiber optical transceiver over 60m 100ms 2000 1 3 SONY SHADCCD...

Page 31: ... GND 18VDC J10 Power supply input supply DC 18V for the station GND Unlock signal output output pulse 12V voltage to system power supply to unlock Data transmission Network port J7 485B 485A To WRT lift controller To WRT lift controller GND MENCI To door contact controller GND ...

Page 32: ...upply 2 Check if electric lock is match 3 Check connection of network wire 1 Use PIN to release door if it works the problem is the wiring between Gate Station and system 2 If PIN cannot release door please test if there is 12V between LOCK of Gate Station and NO port of system power supply when release door If no voltage in LOCK please change Gate Station If there is voltage in NO please change e...

Page 33: ...ized and unlock when power off please connect according to actual situation Door contact 18V GND PUSH NO NC Electric lock HD V18 2 RVV2 1mm 2 RVV3 1mm 18V UNLOCK GND ENC 485A GND 485B JP2 1 2 3 External connector 1 External connector 2 To LAN Cable Gate Station To lift controller ...

Page 34: ...RT Industrial Base Dafu Industrial Park Guanguang Rd GuanLan Town BaoAn District ShenZhen China Tel 86 755 29576113 Fax 86 755 29576023 Http www wrtsz com Shenzhen WRT Intelligent Electrical Appliance Co Ltd ...

Reviews: