background image

Instruction

 (

Version: H2)

Thank you for choosing WRT. Please read this manual before 

using. WRT reserves the right to change specifications or designs 

described in this manual without notice and obligation.

TZS-801ZCD8S7

A/A

,H

Ide

nti

fie

r

Summary of Contents for TZS-801ZCD8S7

Page 1: ...sion H2 Thank you for choosing WRT Please read this manual before using WRT reserves the right to change specifications or designs described in this manual without notice and obligation TZS 801ZCD8S7 A A H Identifier ...

Page 2: ...tent Content 1 0 Features Functions 2 0 Equipment Description 3 0 Caution 4 0 Installation 5 0 Operation 6 0 Specification 7 0 Terminal Description 8 0 Trouble Shooting 9 0 Wiring 1 3 2 4 5 28 29 30 31 32 ...

Page 3: ...unted install 3 7 0 LCD Display monitor the situation of the entrances 4 Remote unlock 5 Can call the Control Center Control Center can know through the station if there is any emergence 6 Call the other tenant for intercom 7 Ringtone Download and Silent Mode 8 Function for lift 9 Divert 10 Home furnishings control only for the Home Extension 11 Check pictures SMS ect 12 Service for the convenienc...

Page 4: ... Detector 12 Socket of lift 13 External Socket for the power of emergence and alarm select 14 Socket for Unit Module Type A H 15 Connection Socket for audio and data of the Front Door Station 16 Connection Socket for video of the Front Door Station 17 Connect Socket for output of 180VDC 18 Socket for Fire Detector PIR 12VDC 0 5A power output 2 1 GND 18V V I N 485 B 485 A AU OUT AU IN G N D GND 12V...

Page 5: ...heating equipment or cooking surfaces 2 Be sure to cut off the power during installation 3 Do not attempt to change or alter the equipment It can cause fire or electric shock 4 Do not plug or unplug with wet hands Electric shock could result 5 Do not use any power source other than specified Fire or electric shock could result 6 Make sure wires are connected properly before plugging in power suppl...

Page 6: ...ll box through the inlet Figure 1 2 Make 4 screw holes according to the positioning card and then drive the cement plugs into the 4 screw holes through the inlet Figure 2 3 Use flat tool to open the front decorative cover Figure 3 4 After connecting door phone wires fix the door station on the wall with 4 screws Figure 4 5 Fix the cover hole wall 86 box Figure 1 Figure 2 Figure 3 Figure 4 wall Pri...

Page 7: ...ice Monitor Smart home Call Message Home Settings Help icons in homepage Touch can turn off the screen it will turn in screen saver or shut down if there is no operating after 3 mins Settings Specification of the door phone must be set after connect well Press setting icon turn to the interface where you can set password room number and so forth Password Touch the icon of Password and input the ol...

Page 8: ...are not set up when it is green arm zones are set up when it is yellow there is a new alarm when it is red 8 Alarm Zones in all Zones 1 to 4 are for fire gas FIR and door sensor 5 to 8 would be set by your own You have to set up the arm zones first Touch the Alarm icon input the password and press to confirm Touch Alarm Zone icon click the zones to arm them and click to confirm click the armed zon...

Page 9: ... to confirm Disarm all Click Disarm all and click to confirm Note Smoke and Gas zones will turn to arming status after setup Arm Disarm it works only if it is home mode Click the arm zone you need and press if toot sound is heard the alarm LED turns to yellow Click again the armed zone s you want to disarm and click to confirm for disarm purpose 7 Operation Operation ...

Page 10: ...t be deleted Lock Unlock the selected ringtones Play the selected ringtone A dialogue box will show after click to remind user whether to set it and Slip up down to check other ringtones Select the call in locations by or and press to confirm press to back to previous menu Option Guard center Ring 8 Operation Operation ...

Page 11: ...ode you want For example select Guest press to delete the former information press numbers to input new data Set other scenes like this Refer to the manual of home automation system for details Smart Home Type A H Set for the home automation function The door phone can be used as control panel in RF wireless home automation system and ECB bus home automation system but the settings are different f...

Page 12: ...re are settings before or default settings are not cancelled it will show Clearing all settings Yes or No for choices User press or to choose the room or appliance to control and click to confirm and enter into appliance configuration interface click or choose Cbus as devices type 10 Operation Operation ...

Page 13: ...based on hexadecimal system For example set address No for device which physical address is 1234 the 3rd port device address 1X16 2 18 sub address 3X16 4 52 port No 3 It will update database in sensor every 60 seconds if there is a sensor system and automatically show updated data on main interface Profile timer Set one scene for the time point of everyday Click Profile timer it will show Time adj...

Page 14: ...on to set snapshot key tone screen saver enable analogous door phone and so forth Touch the function you want to set means turn on means turn off press key to save the data and go back to previous The station will snapshot after 5 seconds while the station is calling the indoor monitor under the snapshot is on It also snapshot after 5 seconds while the Front Door Station is calling and the photo w...

Page 15: ...tivated it will cancel No disturb on status Cancel divert on status click Cancel divert on and click confirm icon in divert on status Color Touch Color to adjust brightness contrast and saturation There are totally 100 levels press to save the data and go back to the previous Volume Touch Volume There are totally 50 levels of the Ring Volume 6 levels of the High Volume 14 levels of the Low Volume ...

Page 16: ...ll will not ring after successful setting The divert on setting will shut down when No disturb on Cancel No disturb on The icon will turn to cancel No disturb on status after setting successfully User click Cancel No disturb on and confirm it to cancel No disturb on function Delay Settings Touch Delay Settings Input the time and press key and confirm it 14 Operation Operation ...

Page 17: ... cautious of this step Please restart the device after setting all above Call Touch Call icon Guard Center This function is used for calling the Control Center If no answer it will cut off automatically or else the call can be kept in 2 mins Tenant Touch Tenant icon Dial Format Setting Set the length of the No Input RULE and press key to confirm 15 Operation Operation ...

Page 18: ...t in 2 mins You can also add new contacts by inputting the Room No of the tenant and press Add Contacts to save You can check the numbers by touching Check Contacts Duty Manager Click it and call to lobby manager center Monitor The station can monitor 30 seconds Touch Monitor to select Gate Station Sub Gate Station or Entrance Station for monitoring Use Page up or Page down to turn the pages and t...

Page 19: ...cords except for the locking one Delete the records which have been selected locking records can t be deleted Lock the records which have been selected to avoid to be deleted Unlock the locking records which have been selected so that it can be deleted and use for page turning when there are lots of records 17 Operation Operation ...

Page 20: ... selected locking records can t be deleting Lock the voice records which have been selected to avoid to be deleted Unlock the locking voice records which have been selected so that it can be deleted Play and voice records which have been selected Back to the previous menu Picture Touch Picture to check snapshot pictures the screen will show while touched 18 Operation Operation ...

Page 21: ... Lock the photos which have been selected to avoid to be deleted Unlock the locking photos which have been selected so that it can be deleted to take a look at the photo and functions use for page turning when there are lots of photos Message Touch Message to check the records the screen will show while touched 19 Operation Operation ...

Page 22: ...ellow from white then click the icon to read the message and use for page turning when there are lots of messages The LED will be turn to red when there is any new message Home Outside Express mode one key arm disarm conveninent for users to control arm zones Click Home icon then confirm it to set arm for all arm zones they will start to work after delay time Click Outside icon input password and ...

Page 23: ...y problem water supply problem Kitchen problems etc Users can click and to choose the type of helping service Then click to send the signal to the guard center If succeed you will see a message box click OK to confirm Fee Check You can check the fee for water electricity gas management drinking water and heating bills Click and to choose the type of bill and then click to check the bill 21 Operati...

Page 24: ...llowing screen To download the ring tone from the center to the door phone You can set the ring tone downloaded in Ring Setting Download the ring tone from the center to buffer and play and When there are many ring tones press to turn the pages Living message Ask for handy service from the center Only when the center offer this service Voice Message Leave a message 22 Operation Operation ...

Page 25: ...service center to get services To realize this function an IP telephone server and the telephone traffic platform Alarm Clock Users can set alarming time under this menu Smart Home Touch Smart Home Scene Select the scene you want by touching the icon For example click Guest it will show Confirm Succed 23 Operation Operation ...

Page 26: ... device to control Being Called When the Gate Station or Sub Gate Station or Front Door Station is calling the station rings and the screen shows the situation of the doorway Press Intercom to have a conversation with the visitor Press Snapshot to take a photo Press Silent to shut down the rings Press Hand Off to end the call Press Unlock while talking can release the lock When the Control Center ...

Page 27: ...e then do it by the fast mode if it is separate control zone then disarm by that Fire Gas If there dangerous it will alarm under the armed state and send the message to the Guard Centre at the same time PIR Magnetic Contact After armed if don t handle the alarm during the arm delay time then start checking if there is arm happened if don t disarm in 40s then it will send the information to the gua...

Page 28: ...of the door phones can call or monitor separately 3 All the phones can receive calls at one time You can use and only use any one of them to answer The other three door phones can receive other calls at this time In a word three door phones can receive calls from three different ways 4 Door phones can connect with each other input R1 stand for the main door phone R2 R3 R4 can call the relevant doo...

Page 29: ...lug the door phone cannot work normally add a storge battery is suggested 3 There are socket for connect external alarm input J1 and J13 pin socket at the back of the door phone It turns to NC Alarm when J1 plug in but J13 unplug in short circuit if the alarm input disconnect to GND the station alarm It turns to NO Alarm when J13 plug in but J1 unplug in short circuit if the alarm input and GND sh...

Page 30: ...inch 7 0 inch Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes LCD Call Intercom Unlock Monitor Alarm Smart Home Arm Disarm Lift call Message Divert on No disturb Help Ring download Multi monitors Remote upgrade ...

Page 31: ...gnal System Power Output Number of Pixels Screen Size Time Out Period Network Port Way of Transmission Transfer Distance External Dimensions 45 95 18VDC 7 0 LCD 384000 dots diagonal 17 5cm 7 0 Build in 12 dots PAL NTSC 85 180s 200mA 20 LCD Closed 350mA 20 50mW 20mV 5 255x178x32mm 10 C 55 C 0 0 RJ45 TCP IP use a decoder or router in 60m add a fiber optical transceiver over 60m ...

Page 32: ...ignal Socket of lift External Emergency Button Ground Wire External Alarm ALARM OUTPUT GND ALARM INPUT Socket of Alarm 18VDC Voltage Input Ground Wire 18VDC GND Socket of Power Supply Input Door Phone supplies 12VDC power to Fire Detector Ground Wire Door Phone supplies 12VDC power to PIR PIR GND FIRE Socket of Detectors supply power Fire Detector switch signal input Magnetic Contact switch signal...

Page 33: ...hows no image Reset all the IPs Connect the network wire correctly and set the specification correctly Check the specification of network Detectors cannot alarm Check the defence zones Check the connection of the detectors Connect all the sensors correctly and reset door phones Input the room numbers correctly Door Phones cannot call each other Check if input correct number Check the wire connecti...

Page 34: ...truction 8 7 6 5 4 3 2 1 报警输入 GND 报警输出 节点1 节点2 TZS 801ZCD8S7 GND 18V V IN 485 B 485 A AU OUT AU IN GND GND 12VDC 485 B 485 A GND AU IN AU OUT 12V VIDEO GND 15V GND LOCK DZH 801C LK L L WRT SD power e lock 8 7 6 5 4 3 2 1 SMOKE GND PIR GND GND NC NO NC NO D7 D8 MC PIR GAS SMOKE NC NO 12V GND GND GND GND GND GND NC NO 12V NC NO NC NO NC NO NC NO D5 D6 12V to Lift to LAN Alarm bell 12V GND OUT GND sp...

Page 35: ...RT Industrial Base Dafu Industrial Park Guanguang Rd GuanLan Town BaoAn District ShenZhen China Tel 86 755 29576113 Fax 86 755 29576023 Http www wrtsz com Shenzhen WRT Intelligent Electrical Appliance Co Ltd ...