Wren Kitchens BASE 2 MILANO Manual Download Page 1

FITTING GUIDE

L CORNER BASE
CABINET

For Internal Use:CON_INS_002.001_50-WKIN0008_BASE2_MILANO_LCNR_Rev5

Page 1

View from rear of cabinet

Sample cabinet shown

(3)

Ff

Ff

Screws for attaching to walls and countertop are not provided as these vary depending on materials, 

thickness and construction. Ensure appropriate fixings for wall and countertop construction are used. 

Please refer to the specialist countertop supplier if these are required for solid surface countertops.

(H) x8

 1 1/4” Screws

(B) x82

  5/8” Screws

(V) x3

 XL Space-Plug

(K) x3

 L Bracket - Large

(Ff) x10 

Fixing Plate

B

View from underside

(1)

(2)

Ff

Ff

Ff

Ff

Step 1.

Attach Fixing Plates 

(Ff)

 onto cabinets in 3 positions 

(1)

(2)

(3)

 as shown 

using 4 x 5/8” screws 

(B)

 per plate. Be careful not to interfere with leg 

Step 2.

Secure each of the legs into place with 2 x 5/8” screws 

(B).

 Ensure legs 

are rotated as shown so that part of them is supporting the end panel. 

Step 3.

Secure cabinet to the wall using XL Space-Plugs 

(V)

Use a stud finder to locate the studs on the wall, drill pilot holes through  the back brace 

of the cabinet into the wall at the stud locations. Unwind the XL Space-Plugs 

(V)

 until 

they contact both surfaces, insert and tighten an appropriately sized screw through the 
back of the cabinet and the XL Space-Plug 

(V)

 into the wall. (Use appropriate fixing for 

wall construction where a stud is not available)

FI.PK.FIT.014 - BASE 2 MILANO

Reviews: