WPT POWER WPD-05 Installation & Maintenance Manual Download Page 3

Page 

3

 of 

9

 

 

WIM-PD-005 REV_A 

1.0  Introduction 

 
The WPT Power Pump Drive model WPD-05 is an innovative modular pump drive designed to be 
mounted on industrial engines with SAE flywheels and housings. The input is a rugged Rubber Block 
Drive flywheel coupling. This elastic coupling absorbs radial and angular misalignments as well as 
dampens torsional vibrations. The model WPD-05 output is a dual pad pump drive as well as SAE 
flywheel and flywheel housing. To allow for easy installation the pump tower can be mounted in 12 
possible positions over 360 degrees. The output flywheel can accept transmissions, pumps, 
compressors, 

and PTO’s.

 

 

Throughout the manual there are several HAZARD WARNINGS that must be read and followed to 
prevent possible loss of equipment and/or personal injury and/or loss of life. The three warning words 

are “DANGER”, “WARNING” and “CAUTION”. They are used to indicate the severity of the hazard and 

are preceded by a safety alert symbol. 

 

 DANGER 

Denotes the most serious injury hazard and is used when serious injury or death WILL result from 
misuse or failure to follow the specific instructions sit forth in this manual. 

 

 WARNING 

Denotes when serious injury or death MAY result from misuse or failure to follow the specific 
instructions set forth in this manual. 
 

 CAUTION 

Denotes when injury, product or equipment damage may result from the misuse or failure to follow 
the specific instructions set forth in this manual. 
 

2.0  General Warnings 

 
Before assembling and operating the product, carefully read all the safety and operating instructions in 
this manual. 
 
Always follow all the instructions and make sure that all operators standing by the machinery are 
wearing protective equipment necessary for the job type and application being performed. 
 

 WARNING 

Do not use the machinery if you do not understand these instructions. Please refer to the 
manufacturer or customer service for assistance. 

 

 WARNING 

The product must be protected by a convenient cover guard to avoid personal injury or injury to 
others. 

 
Axial and radial ventilation openings should be incorporated in the guard for heat dissipation. 
 

Summary of Contents for WPD-05

Page 1: ...POWER PUMP DRIVE PPD Installation Maintenance Manual Model WPD 05 Belt Drive ...

Page 2: ...3 3 0 Installation ____________________________________________________________ 4 4 0 Maintenance___________________________________________________________ 5 5 0 Belt Replacement _______________________________________________________ 5 6 0 Exploded View _________________________________________________________ 6 7 0 Bolt Torque Specifications ________________________________________________ 8 ...

Page 3: ...ANGER Denotes the most serious injury hazard and is used when serious injury or death WILL result from misuse or failure to follow the specific instructions sit forth in this manual WARNING Denotes when serious injury or death MAY result from misuse or failure to follow the specific instructions set forth in this manual CAUTION Denotes when injury product or equipment damage may result from the mi...

Page 4: ... 3 Mount the pump drive on the flywheel housing of the engine keeping in mind to align the teeth of the elastic coupling in the respective teeth of the driving ring To align the pump drive housing and flywheel housing use three threaded rods with adequate lengths mounted 120 apart on the flywheel housing To perform this operation lift the assembly by using straps or other approved means In cases w...

Page 5: ...djustments have been made to confirm No lubrication is required for this unit All bearings are sealed for life which require no maintenance 5 0 Belt Replacement To replace the belt follow steps below See exploded view in section 6 5 1 Remove pump drive from engine 5 2 Remove rubber block coupling assembly key 8 9 12 5 3 Remove flywheel from output side 33 32 5 4 Remove bolts to separate belt housi...

Page 6: ...REW 12 1 COUPLING 13 1 HOUSING 14 1 SHAFT 15 1 KEY 16 2 BALL BEARING 17 2 INNER SNAP RING 18 1 PULLEY 19 2 OUTER SNAP RING 20 5 SCREW 21 10 WASHER No Qty DESCRIPTION 22 1 COVER 23 2 WASHER 24 2 SCREW 25 3 PIN 26 5 SHCS 27 1 HOUSING 28 12 SCREW 29 12 WASHER 30 1 SPACER RING 31 1 SNAP RING 32 1 DUMMY FLYWHEEL 33 5 SCREW 34 2 PIN 35 1 BRACKET 36 1 BELT 37 1 PLATE 38 4 M5X12 8 8 SHCS 39 2 SHCS 40 2 M1...

Page 7: ...Page 7 of 9 WIM PD 005 REV_A ...

Page 8: ...3 1 3 4 3 4 5 2 5 0 8 4 6 6 8 5 7 10 1 6 1 8 10 4 11 14 6 13 17 5 7 1 12 15 7 16 22 19 26 4 8 1 25 18 24 6 26 34 7 31 41 6 10 1 5 37 50 1 52 70 5 62 84 6 12 1 75 63 84 8 88 119 105 143 14 2 100 135 140 190 168 228 16 2 151 205 212 288 255 346 18 2 5 209 283 294 398 353 478 20 2 5 295 400 415 562 497 674 22 2 5 392 532 552 748 662 897 24 3 510 691 716 971 863 1170 27 3 745 1010 1047 1420 1254 1700 ...

Page 9: ...Page 9 of 9 WIM PD 005 REV_A WPT Power 1600 Fisher Road Wichita Falls TX 76305 P O Box 8148 Wichita Falls TX 76307 Ph 940 761 1971 www WPTpower com ...