Rev 19.3/9-18
17
VL411LDC: #35162
M
AINTENANCE
S
CHEDULE
Unless specified elsewhere in this
INSTRUCTIONS manual, the lifter does not require
maintenance on a routine basis. Instead, maintenance must be performed whenever a
deficiency is indicated by routine inspections or tests. Any maintenance warranted must be
performed before resuming normal operation of the lifter.
B
ATTERY
T
EST
The lifter is equipped with a battery gauge to help the operator evaluate
whether the battery has adequate energy for lifting. Factors such as
the condition of the battery, the time required to execute a lift, and the
porosity of the load combine to determine how much battery energy is
needed.
It is the operator’s responsibility to evaluate these
conditions and to make sure the battery has sufficient energy to
complete a lift safely. Check the battery energy before every lift and
also at the end of each day's use, to decide whether a charge is needed
(see B
ATTERY
R
ECHARGE
to follow).
8
Never use the lifter when battery
energy registers lower than 50% (that is, when only red lights are illuminated), regardless of the
estimated energy requirement.
WARNING: Never use lifter if battery energy is lower than 50% of capacity.
While the valve handle is in the “apply” ( ) position (power on), the battery gauge
automatically monitors battery energy. However, the battery gauge shuts off temporarily while
the vacuum pump is running, to prevent an inaccurate reading. When the pumping cycle is
completed, the battery gauge requires a few moments to stabilize before it displays an accurate
energy reading again.
While the valve handle is in the “release” ( ) position (power off), the battery energy can be
checked manually using the battery test button. If the lifter has not been used since the battery
was charged, the battery gauge may falsely indicate an energy level that is higher than actual,
due to a “surface charge” on the battery. After the pump runs for approximately one minute,
the surface charge dissipates, allowing the operator to take an accurate energy reading.
8
The battery charger must be disconnected from its AC power source in order to test the battery energy; otherwise, the energy
reading on the battery gauge would not be accurate.