Rev 29.0/11-19
P1-DC: #35111
25
MAINTENANCE
Notes: Refer to
SERVICE MANUAL #36110
when applicable. See final section for wiring
diagrams.
V
ACUUM
P
AD
M
AINTENANCE
Pad-to-Load Friction Coefficient
The friction coefficient represents the lifter's ability to resist load slippage.
1
The
Maximum Load Capacity is based on a friction coefficient of 1, as determined by testing
of clean, new, standard rubber vacuum pads on clean, dry, regular glass.
If the lifter is
used under any other conditions, a qualified person must first determine the effective lifting
capacity.
2
Long-term exposure to heat, chemicals or UV light can reduce the friction coefficient of vacuum
pads. Replace pads every 2 years or more often, when necessary.
Pad Inspection
1A
Inspect each vacuum pad (fig. 1A) according to
the “I
” on
correct the following faults before using the
lifter (see “REPLACEMENT PARTS”, when
applicable):
• Contaminates on the face (1) or sealing
edges (2).
• Filter screen (3) missing from face.
• Nicks, cuts or abrasions in sealing edges.
Replace any pad that has damaged
sealing edges.
• Wear, stiffness or glaze.
1..... Not applicable to Flat Lifters.
2..... A “qualified person” has successfully demonstrated the ability to solve problems relating to the subject matter and work, either by possessing a
recognized degree in an applicable field or a certificate of professional standing, or by possessing extensive knowledge, training and experience.
Summary of Contents for P110C04DC
Page 2: ...P1 DC 35111 Rev 29 0 11 19 2...
Page 6: ...P1 DC 35111 Rev 29 0 11 19 4 SPECIFICATIONS Note A standard P11104DC is shown...
Page 32: ...P1 DC 35111 Rev 29 0 11 19 30...
Page 33: ...Rev 29 0 11 19 P1 DC 35111 31...
Page 34: ...P1 DC 35111 Rev 29 0 11 19 32...
Page 35: ......
Page 36: ......