MT-10TDC-HV-C: #35094
Rev 17.2/12-21
30
B
ATTERY
R
ECHARGE1
Charge the battery whenever the battery gauge shows reduced energy.
2
Caution:
Make sure
the lifter is powered down.
Make sure power source has
ground fault circuit interrupter.
Identify the input voltage marked on the battery
charger and plug it in to an appropriate power
source.
3
Press the “MODE” button to select “NORMAL”
mode. Lights 1-4 indicate the charging level
attained.
4
When the battery is fully charged, light
4 (green) turns on and the charger switches to
maintenance mode.
The battery should take no more than 8 hours to
charge completely.
5
After reaching level 3, the
charger analyzes the battery condition. If the
battery needs to be replaced, the charger's red
error light (!) turns on (see
).
Before you return the lifter to service, recheck the
battery as previously directed.
1..... You may use a battery charger other than the one supplied, provided it is designed for 12-volt DC, AGM type, lead-acid batteries. Disconnect
the battery from the vacuum generating system before charging.
2..... To maximize the battery's lifespan, charge it promptly after each use.
3..... Any external power supply must conform to all applicable local codes. The lifter is not intended for use while the charger is connected to AC
power.
4..... If none of the charging level lights turns on, the battery connection or the battery itself may be faulty. If the red error light (!) turns on
immediately, the battery leads may be reversed or the charger terminals may be short-circuited; once the problem has been corrected, the
charger should function normally. The red error light can indicate other problems, depending on the mode selected and level of charging; if
necessary, contact WPG for assistance.
5..... The charger automatically reduces the charging rate when the battery is fully charged.