MT-10TDC-HV-C: #35094
Rev 17.2/12-21
18
T
O
L
IFT
AND
M
OVE
THE
L
OAD
Interpreting the Warning Light
Never lift load unless warning devices turn off, because
this could result in load release and personal injury.
When vacuum is
sufficient to lift the
Maximum Load Capacity,
the vacuum pump and the low vacuum warning light turn off temporarily, to conserve battery
energy.
When air leaks into the vacuum system, the vacuum pump turns on and off (along with the
warning light) as necessary to maintain sufficient vacuum for lifting.
Monitoring Vacuum Indicators
1A
Monitor the low vacuum warning light and the vacuum
gauge (fig. 1A) throughout the entire lift.
Make sure vacuum indicators remain
completely visible.
If the warning light turns on and the
vacuum gauge
shows a level less than 16" Hg [-54 kPa]
:
1) Keep everyone away from a suspended load until
it can be safely lowered to a stable support.
Stay clear of any suspended load while
indicators warn of low vacuum.
2) Stop using the lifter until the cause of the vacuum loss can be identified: Conduct the
3) Correct any faults before resuming normal operation of the lifter.