11
•
Make sure you review each warning in order to prevent fire hazard.
•
Keep area clear of in flammables or other hazardous materials.
•
Keep generator at least 3 feet (1 meter) away from buildings or other structures.
•
Only operate generator in a dry, well ventilated area.
•
Keep exhaust pipe clear of foreign objects.
•
Keep generator away from naked flame. No smoking!
•
Keep generator on a stable and level surface.
•
Do not block generator air vents with paper or other material.
4.4. GrounDInG the Generator
•
Before using the generator, the grounding lug on
the panel must be connected to the earth.
•
To ground the generator to the earth, connect the
grounding lug of the generator to the grounding
spike driven into the earth or to the conductor
which has been already grounded to the earth.
•
If such grounding conductor or grounding
electrode is unavailable, connect the grounding
lug of the generator to the grounding terminal of
the using electric tool or appliance.
Earth Terminal
4.5. eLectrIc starter (optIonaL)
The battery is delivered dry but loaded. You have to fill it with acid before using.
1. Just before filling the battery, take out the plastic cap and connect the hose to the mechanical out
connection.
2. Remove the tank cap and fill fully with electrolyte until the maximum level written on the battery.
3. Let the battery rest for a while (roughly 1/2 HRS) before running by a load. If the electrolyte level
dropped, fill again until the maximum level.
4. If necessary, reload the battery. The loading can be made with unscrewing the filling caps.
5. Remove the plugs and clean the electrolyte that fell down on the battery. The battery is ready for use.
aBout the BatterY caBLes
1. Fix the positive (+) wire connected to the
electrical starter to the positive terminal of the
battery
2. Fix the negative (-) wire connected to the
housing of the engine to the negative terminal
of the battery.