2 user-defined functions that can monitor one of the following:
o
Ambient temperature
o
Heatsink temperature
o
Fan 1 speed (or fan 2)
o
Amplifier voltage
o
Amplifier current
o
Amplifier power
And seven monitoring functions are associated with relays:
•
Local: indicates if the unit is in local mode
•
Fault: indicates a transmitter fault
•
Warning: indicates an alarm linked to the internal working of the transmitter (temperature, voltage…)
•
RF: indicates if the RF is enabled
•
On: indicates if the transmitter is not in standby mode
•
Off: indicates if the transmitter is in standby mode
•
VSWR: indicates if there is a VSWR error
10.3.2.
Remote control function pinout
Function
Remote Control
Input name
Common
POWER ON
RC1
OPT1(20)
RC_COMMUN(24)
POWER OFF
RC2
OPT2(8)
RC_COMMUN(24)
RF ON
RC3
OPT3(21)
RC_COMMUN(24)
RF OFF
RC4
OPT4(9)
RC_COMMUN(24)
Numbers in parenthesis indicated the pin number on the DB25 connector.
* The GPIO board can be used to manage presets. See section 8.4.2 for more details.
10.3.3.
Remote analog monitoring function pinout
Event
Remote Monitoring
Output name
Common
FORWARD POWER
RM ANA 1
ANA_OUT_A(11)
GND(25)
REFLECTED POWER
RM ANA 2
ANA_OUT_ B(23)
GND(25)
CONFIGURABLE* 1
RM ANA 3
ANA_OUT_ C(10)
GND(25)
CONFIGURABLE* 2
RM ANA 4
ANA_OUT_ D(22)
GND(25)
Numbers in parenthesis indicated the pin number on the DB25 connector.
* CONFIGURABLE: T AMB or FAN 1 or V1+V2/2 or HEAT SINK or FAN 2 or I1+I2 or PWR or SW STATUS
SW Status: 0=Manu / 1V= Auto + Swit Reserve KO / 2V=Auto + Swit Reserve Ok / 3V=Auto + Reserve
KO / 4V=Auto + Reserve Ok / Preselect 2 = + 0.5