NAME
Access
(R/W)
Possible value
on the serial
port of the unit
Comments
RDS.STATIONNAME.SHORT.STR
R/W
[A…Z]
Sets the command that modifies <STATIONNAME.SHORT>;
default value: STATIONNAMESHORT
RDS.VOTE.CENTER.STR
R/W
[A…Z]
Sets the command that modifies <VOTE.CENTER>; default value:
VOTECENTRE
RDS.VOTE.QUESTION.STR
R/W
[A…Z]
Sets the command that modifies <VOTE.QUESTION>; default
value: VOTEQUESTION
7.2.9.
Status commands
Commands in bold are Ecreso FM Amplifier and Ecreso FM with integrated amplifier (300 W to 2000 W) only
commands.
NAME
Access
(R/W)
Possible value on the serial
port of the unit
Comments
STAT.10M
R
"PRES" or "NOT PRES"
Indicates the presence of an external 10 MHz
STAT.1PPS
R
"LOCK" or "UNLOCK"
Indicates the presence of an external 1 PPS
STAT.CLK
R
"INTERNAL" or "EXTERNAL"
Indicates the 10 MHz switch position
STAT.CURRENT.IN
R
"1+OPT" or "1+2" or "2+OPT"
Indicates the channels used for channels 1 and 2
STAT.DCOK1
R
"ON" or "OFF"
Indicates if the PSU 1 of the amplifier is "ON" or "OFF"
STAT.INTERLOCK
R
"CLOSE" or "OPEN"
State of the antenna safety loop
STAT.INTERLOCK.LOAD
R
"CLOSE" or "OPEN"
State of the load safety loop
STAT.LINK
R
"OPEN" or "CLOSE"
State of the CAN bus link
STAT.PLL
R
"LOCK" or "UNLOCK"
Indicates the state of the exciter PLL
STAT.PREFMAX
R
"ON" or "OFF"
ON: Max Reflected Power Safety overshoot
STAT.RF
R
"PRES" or "NOT PRES"
RF present at the output of the unit
STAT.SECPIN
R
"ON" or "OFF"
Indicates if the input power is greater than the
hardware threshold
STAT.SECPREF
R
"ON" or "OFF"
Indicates if the reflective protection safety is enabled
STAT.SECTEMP1
R
"ON" or "OFF"
State of the temperature safety of the amplifier
transistor 1
STAT.SECTEMP2
R
"ON" or "OFF"
State of the temperature safety of amplifier transistor
2 (1500 & 2000 W modules only)
STAT.SWRF
R
"ON" or "OFF"
State of the RF switch
7.2.10.
Communication board commands
NAME
Access
(R/W)
Possible value on the serial port of
the unit
Comments
CAN
R/W
ID,CMD,DATA ; ID=[0…9];
CMD=[0…FF] DATA=[0..9 ; A…Z]"
Gateway between the serial port and the CAN bus. ID=recipient’s
address; TABLE=table containing the command; CMD=command
number; DATA=parameter value. The list of tables/commands is
available on request.
CAN.SCAN
R/W
Returns the list of units present of the CAN bus.
Commands related to options are only available when the option is present.