9.5.2.
Dynamic Encoder
The dynamic encoder can be set using serial commands (see section 7.2.8) or the web interface but not with the front
panel.
PS Scroll
Path:
RDS
/Dynamic Encoder/PS Scroll
Set the PS scroll on this page.
For each line of PS text, set:
Text:
Text may include dynamic data (<ITEM….>, <INFO…>…) that will only be sent if filled in, and for ITEM
type fields if the validity time frame is correct.
Repetition
: Then encoder will repeat the line before sending the next one (max: 99 times).
Enabled
: Check the box for the line to be sent.
Center:
When scrolling is done word by word, the encoder may center each word in the receiver screen. Only
applicable when ‘Word’ is the chosen increment
Truncated:
Set the number of scrolling characters. Scrolling may be done by word. In that case, the encoder
will detect whole words (identifiable delimiters are: ‘ ‘, ‘-‘, ‘,’), and fit as many whole words as possible on
each screen.
Increment:
When scrolling is done word by word, the encoder truncates words longer than the display screen
(longer than 8 characters). Only applicable when ‘Word’ is the chosen increment.
Delay:
Time laps between 2 consecutive screens.