4. COMMUNICATION PROTOCOL DESCRIPTION
4.5.3 Get manual range
Returns the currently set manual thermal range minimum and maximum.
Command
•
GRMM
Answer
•
20.0 40.0
4.5.4 Set manual range
Sets the thermal manual range minimum and maximum
Command
•
SRMM 20.0 40.0
Answer
•
OK
4.5.5 Get span range
Returns the current span range window and center.
Command
•
GRWC
Answer
•
10.0 30.0
4.5.6 Set span range
Sets the manual range window and center
Command
•
SRWC 10.0 30.0
Answer
•
OK
4.5.7 Get environment
Returns current thermal environment (absolute temperature range) se ng.
Command
•
GREN