![Worcester GR2300iW C Installation And Maintenance Instructions Manual Download Page 90](http://html.mh-extra.com/html/worcester/gr2300iw-c/gr2300iw-c_installation-and-maintenance-instructions-manual_996431090.webp)
Technical Specifications/Logs
Greenstar 2000 – 6 721 820 552 (2021/02)
90
Table 40 Technical data Greenstar 2000 LPG
13.2
Component resistance characteristics
13.3
Heating curve
Fig. 106 Heating curve
A
End point (at the outside temperature – 10 °C)
AT
Outdoor ambient temperature
B
Base point (at the outside tempe 20 °C)
max
Maximum flow temperature
pA
Flow temperature at the end point of the heating curve
pB
Flow temperature at the foot point of the heating curve
S
Automatic heating switch-off (summer mode)
VT
Supply temperature
General data
Expansion vessel capacity
l
6
6
Expansion vessel pre-charge pressure
bar
0.75
0.75
Appliance protection rating
4)
IP
X4D
X4D
Permissible ambient temperature short-term/long-term
°C
0-50/40
0-50/40
Nominal capacity of the appliance
l
7
7
Total package weight
kg
40
40
Total appliance weight (excluding packaging)
kg
36
36
Lift weight (without front panel)
kg
33.4
33.4
SEDBUK 2009
%
91
91
1) For minimum and maximum permissable pressure refer to “Gas pressure within the system”, section 6.6.
2) Propane/butane mixture for fixed containers with capacity up to 15 000 litres.
3) Appliances are fitted with a flow regulator set to achieve a 35°C temperature rise. A 40°C temperature rise is possible at lower flow rates.
4) Protection rating may change depending on the control unit/s used on this appliance.
Greenstar 2000
GR2300iW C
Description
Unit
25kW LPG
30kW LPG
AT/°C
VT/°C
0 010 005 905-001
B
S
+20
max
pA
pB
-10
A