Installation
Greenstar 2000 – 6 721 820 552 (2021/02)
42
Replaceable mains cable (power cable) and 230v external controls
connections.
▶ Release the catches [1] and remove cover.
Fig. 54 Remove cover
▶ Remove the cable clamp.
▶ For splash protection (IP): Cut the strain relief according to the
diameter of the cable [1].
▶ Unscrew the cable retaining screw [2].
▶ Guide the cable through the strain relief.
▶ Tighten the cable retaining screw [2] to secure the cable.
▶ Replace the cable clamp.
▶ Connect the cable to the terminal block for external accessories.
Fig. 55 Cable feed
External accessories terminal strip
Control unit
Table 20 Terminal strip for external accessories (Control unit)
230V external controls interface box
Table 21 Terminal strip for external accessories (230V interface unit)
Symbol
Function
Signal connection with 230V interface box (factory-
fitted).
Outside temperature sensor.
Not to be used with 3rd party controls, separated extra
low voltage cannot be guaranteed.
Low voltage switching contact for hard-wired
Worcester mechanical controls.
Not to be used with 3rd party controls, separated extra
low voltage cannot be guaranteed.
Communication BUS connection for hard-wired
Worcester/Bosch EMS controls.
Low voltage power supply for hard-wired Worcester
mechanical controls.
0010033634-001
1
1
0010027249-001
3
2
2
1
≥ 5mm
Control unit 230V power supply connection
Fuse
Symbol
Function
230V mains and external controls connection.
230V feed output and switch live/demand input for
external controls.
• External controls switch live/demand (Live Return)
to the appliance [LR].
– Remove link between LR and LS when
connecting external 230V controls.
• Live output [LS] to external controls.
• Neutral output [NS] to external controls.
• Earth to be connected on earth bar within the 230V
external controls interface unit.
230V Mains connection (power cable)
• Neutral input [N]
• Live input [L]
• Earth is connected to earth bar within the 230V
external controls interface unit.
Fuse
Symbol
Function
N L
230V
IN
Fuse
5AF
Fuse
5AF