C
ONVERSION
KIT
S
INSTALLATION & SERVICING INSTRUCTIONS
48
L.P.G. CONVERSION
8 716 115 219b (09.2008)
Change code plug:
1
Release three screws (A) to remove cover
(B).
2
Remove and dispose of the existing code
plug (C).
Replace with new conversion code plug.
N.G. code plug number:
440CDi 1700
550CDi 1702
L.P.G. code plug number:
440CDi 1701
550CDi 1703
Refit panel (B) and secure with three
screws (A).
Change gas pipe:
4
Rotate gas pipe (D) anti-clockwise, pull
upwards and remove gas pipe.
5
Replace with new conversion gas pipe
(E), push downwards and rotate clockwise
to lock into position.
Conversion label:
Replace existing label with new
conversion label.
Adjust the CO
2
level:
After re-assembly check CO/CO
2
levels
as described in the section “Setting the
air/gas ratio”.
L.P.G. CONVERSION
D
3
4
a
E
b
c
a
b
c
B
A
C
2
1