Model 205 Fireview Rear Heat Shield Installation 

 

 
Please read all of the instructions before you begin the procedure. Confirm that you have 
all the necessary tools and parts required. If you have any questions, technical support is 
available toll free at 1-800-866-4344, Monday – Saturday 9:00- 5:00, ET. 
 
 

Tools Needed: 

 
-7/16” wrench 
- 5/32” allen wrench 
 
 

Materials Needed: 
 

- Fireview rear heat shield Part# W-405 or W-406 (to accommodate an outside air   
adapter) 
- (2) 1” spacers 
- (2) 1 

¼

” bolts 

 
 
The rear heat shield is designed to reduce the required clearance to combustibles behind 
the Fireview stove from 30 inches to 18 inches, in a parallel installation, or 12 inches 
from the rear corners of the stove to the side walls in a corner installation. Pipe clearances 
must be maintained as well, and can be reduced with a separate pipe shield, close 
clearance pipe, or appropriate wall shielding. Do not paint the interior of the heat shield; 
to be most effective it must remain reflective.  

Note:

 If you are installing the rear heat shield in addition to an outside air adapter, one 

bolt and spacer included with the shield will replace the button head bolt that secures the 
left side of the adapter to the stove. 
 
 
1.

 

Make sure the stove is cool. 

 
2.

 

Remove the two outermost button head bolts from the back of the flue collar with the 
5/32” allen wrench. 